Back to search

Division of Emergency Medicine

A Trigger-Tool-based Description of Adverse Events in Helicopter Emergency Medical Services in Qatar

Abstract

dc:description.abstract

Introduction Adverse Events (AEs) in Helicopter Emergency Medical Services (HEMS) remains poorly reported, despite the potential for harm to occur. The Trigger Tool (TT) represents a novel approach to AE detection in healthcare. The aim of this study was to retrospectively describe the frequency of AEs and their Proximal Causes (PCs) in Qatar HEMS. Methods Using the Pittsburgh Adverse Event Tool (PittAETool) to identify AEs in HEMS, we retrospectively analyzed 804 records within an existing AE TT database (21-month period). We calculated outcome measures for Triggers, AEs, and Harm per 100 patient encounters, plotted measures on Statistical Process Control (SPC) charts, and conducted a multivariate analysis to report harm associations. Results We identified 883 Triggers in 536 patients, with a rate of 1.1 Triggers per Patient Encounter, where 81.2% had Documentation Errors (n=436). An AE and Harm rate of 27.7% and 3.5% respectively was realized. The leading PC was Actions by HEMS Crew (81.6%; n=182). The majority of harm (57.1%) stemmed from the Intervention and Medication triggers (n=16), where Deviation from Standard of Care was common (37.9%; n=11). Age and diagnosis adjusted odds was significant in the Patient Condition (6.50; 95% CI, 1.71-24.67; P= 0.01) and Interventional (11.85; 95% CI, 1.36-102.92; P= 0.03) trigger groupings, while age and diagnosis had no effect on Harm. Conclusion The TT methodology is a robust, reliable, and valid means of AE detection in the HEMS domain. Whilst an AE rate of 27.7% is high, more research is required to understand prehospital clinical decision-making and reasons for guideline deviance. Furthermore, focused quality improvement initiatives to reduce AEs and Documentation errors should also be addressed in future research.

Degree

thesis:*
Grantor
Division of Emergency Medicine
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Heuer, Calvin
Advisors dc:contributor.advisor
  • Stassen, Willem
  • Howard, Ian

Subjects

dc:subject × 1

Rights

Language dc:language.rfc3066
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Heuer, C. (2021). <i>A Trigger-Tool-based Description of Adverse Events in Helicopter Emergency Medical Services in Qatar</i>. (). ,Faculty of Health Sciences ,Division of Emergency Medicine. Retrieved from http://hdl.handle.net/11427/35806
Dc Identifier Chicagocitation
Heuer, Calvin. <i>"A Trigger-Tool-based Description of Adverse Events in Helicopter Emergency Medical Services in Qatar."</i> ., ,Faculty of Health Sciences ,Division of Emergency Medicine, 2021. http://hdl.handle.net/11427/35806
Dc Identifier Citation
Heuer, C. 2021. A Trigger-Tool-based Description of Adverse Events in Helicopter Emergency Medical Services in Qatar. . ,Faculty of Health Sciences ,Division of Emergency Medicine. http://hdl.handle.net/11427/35806
Dc Identifier Ris
TY - Master Thesis AU - Heuer, Calvin AB - Introduction Adverse Events (AEs) in Helicopter Emergency Medical Services (HEMS) remains poorly reported, despite the potential for harm to occur. The Trigger Tool (TT) represents a novel approach to AE detection in healthcare. The aim of this study was to retrospectively describe the frequency of AEs and their Proximal Causes (PCs) in Qatar HEMS. Methods Using the Pittsburgh Adverse Event Tool (PittAETool) to identify AEs in HEMS, we retrospectively analyzed 804 records within an existing AE TT database (21-month period). We calculated outcome measures for Triggers, AEs, and Harm per 100 patient encounters, plotted measures on Statistical Process Control (SPC) charts, and conducted a multivariate analysis to report harm associations. Results We identified 883 Triggers in 536 patients, with a rate of 1.1 Triggers per Patient Encounter, where 81.2% had Documentation Errors (n=436). An AE and Harm rate of 27.7% and 3.5% respectively was realized. The leading PC was Actions by HEMS Crew (81.6%; n=182). The majority of harm (57.1%) stemmed from the Intervention and Medication triggers (n=16), where Deviation from Standard of Care was common (37.9%; n=11). Age and diagnosis adjusted odds was significant in the Patient Condition (6.50; 95% CI, 1.71-24.67; P= 0.01) and Interventional (11.85; 95% CI, 1.36-102.92; P= 0.03) trigger groupings, while age and diagnosis had no effect on Harm. Conclusion The TT methodology is a robust, reliable, and valid means of AE detection in the HEMS domain. Whilst an AE rate of 27.7% is high, more research is required to understand prehospital clinical decision-making and reasons for guideline deviance. Furthermore, focused quality improvement initiatives to reduce AEs and Documentation errors should also be addressed in future research. DA - 2021_ DB - OpenUCT DP - University of Cape Town KW - Emergency Medicine LK - https://open.uct.ac.za PY - 2021 T1 - A Trigger-Tool-based Description of Adverse Events in Helicopter Emergency Medical Services in Qatar TI - A Trigger-Tool-based Description of Adverse Events in Helicopter Emergency Medical Services in Qatar UR - http://hdl.handle.net/11427/35806 ER -
Dc Identifier Vancouvercitation
Heuer C. A Trigger-Tool-based Description of Adverse Events in Helicopter Emergency Medical Services in Qatar. []. ,Faculty of Health Sciences ,Division of Emergency Medicine, 2021 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/35806

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Heuer, Calvin. A Trigger-Tool-based Description of Adverse Events in Helicopter Emergency Medical Services in Qatar. Division of Emergency Medicine, 2021. https://hdl.handle.net/11427/35806