Back to search

Department of Human Biology

Design and Development of a Lower Limb Rehabilitation Device for Spinal Cord Injury Patients

Abstract

dc:description.abstract

Introduction: Spinal cord injuries (SCI) are seen commonly in Southern Africa and can completely change the course of the affected's life. Lower limb disability is a common complication from this injury, but a patient can be rehabilitated in some cases. Research and clinical observations suggest that early mobilisation and rehabilitation leads to shorter hospital stays and better clinical outcomes. Relieving the time dedication placed onto the rehabilitation team could mean that patients receive a higher standard of care. Methods: A cyclic movement device has been designed to mimic the gait cycle that a patient is attempting to recover. The device was intended towards providing a ground reaction force simulation at the correct points of the gait cycle. The device was tested in-silico with validated skeletal models to determine joint torques and angles. In-silico testing was also utilised to determine the loads placed onto the patient by the device through its use. The force data could then be used to predict possible ground reaction forces. Results: The device allows for a gait similar trace path of the ankle, comparable to that found in the literature. The ankle has a range of motion of 3 1° as the device completes a full cycle in which the crank rotates 360 °. The hip has a range of motion of 28° and the knee 35° in this same movement. The shape of the displacements of the joints of the lower limb is comparable to that seen in researched gait patterns. However, the timing of the knee and hip joints' movements are not synchronous with that of the gait patterns. The device is validated to be sufficiently stable to use, and the motor and power components can provide the 7259N.mm of torque needed to move the model. Conclusion: The results suggest that the device has potentia l as an adjunct to rehabilitation schemes. In-silico testing showed that the device is able to simulate some of the kinetic and kinematic parameters seen in normal gait. Further work is needed to prototype the device to physically and clinically validate the device.

Degree

thesis:*
Grantor
Department of Human Biology
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Trusler, Matthew
Advisors dc:contributor.advisor
  • Sivarasu, Sudesh
  • Stander, Juliette

Subjects

dc:subject × 1

Rights

Language dc:language.rfc3066
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Trusler, M. (2021). <i>Design and Development of a Lower Limb Rehabilitation Device for Spinal Cord Injury Patients</i>. (). ,Faculty of Health Sciences ,Department of Human Biology. Retrieved from http://hdl.handle.net/11427/36208
Dc Identifier Chicagocitation
Trusler, Matthew. <i>"Design and Development of a Lower Limb Rehabilitation Device for Spinal Cord Injury Patients."</i> ., ,Faculty of Health Sciences ,Department of Human Biology, 2021. http://hdl.handle.net/11427/36208
Dc Identifier Citation
Trusler, M. 2021. Design and Development of a Lower Limb Rehabilitation Device for Spinal Cord Injury Patients. . ,Faculty of Health Sciences ,Department of Human Biology. http://hdl.handle.net/11427/36208
Dc Identifier Ris
TY - Master Thesis AU - Trusler, Matthew AB - Introduction: Spinal cord injuries (SCI) are seen commonly in Southern Africa and can completely change the course of the affected's life. Lower limb disability is a common complication from this injury, but a patient can be rehabilitated in some cases. Research and clinical observations suggest that early mobilisation and rehabilitation leads to shorter hospital stays and better clinical outcomes. Relieving the time dedication placed onto the rehabilitation team could mean that patients receive a higher standard of care. Methods: A cyclic movement device has been designed to mimic the gait cycle that a patient is attempting to recover. The device was intended towards providing a ground reaction force simulation at the correct points of the gait cycle. The device was tested in-silico with validated skeletal models to determine joint torques and angles. In-silico testing was also utilised to determine the loads placed onto the patient by the device through its use. The force data could then be used to predict possible ground reaction forces. Results: The device allows for a gait similar trace path of the ankle, comparable to that found in the literature. The ankle has a range of motion of 3 1° as the device completes a full cycle in which the crank rotates 360 °. The hip has a range of motion of 28° and the knee 35° in this same movement. The shape of the displacements of the joints of the lower limb is comparable to that seen in researched gait patterns. However, the timing of the knee and hip joints' movements are not synchronous with that of the gait patterns. The device is validated to be sufficiently stable to use, and the motor and power components can provide the 7259N.mm of torque needed to move the model. Conclusion: The results suggest that the device has potentia l as an adjunct to rehabilitation schemes. In-silico testing showed that the device is able to simulate some of the kinetic and kinematic parameters seen in normal gait. Further work is needed to prototype the device to physically and clinically validate the device. DA - 2021_ DB - OpenUCT DP - University of Cape Town KW - Biomedical Engineering LK - https://open.uct.ac.za PY - 2021 T1 - Design and Development of a Lower Limb Rehabilitation Device for Spinal Cord Injury Patients TI - Design and Development of a Lower Limb Rehabilitation Device for Spinal Cord Injury Patients UR - http://hdl.handle.net/11427/36208 ER -
Dc Identifier Vancouvercitation
Trusler M. Design and Development of a Lower Limb Rehabilitation Device for Spinal Cord Injury Patients. []. ,Faculty of Health Sciences ,Department of Human Biology, 2021 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/36208

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Trusler, Matthew. Design and Development of a Lower Limb Rehabilitation Device for Spinal Cord Injury Patients. Department of Human Biology, 2021. https://hdl.handle.net/11427/36208