Division of General Surgery
The Reuse of Circular External Fixator Components: An Assessment of Safety and Potential Savings
Abstract
dc:description.abstractPurpose: Cost saving strategies are important especially in a resource constrained environment. One such strategy well supported in literature is the reuse of temporary monolateral external fixator components, a strategy we utilize at our institution. The aim of the study was to determine the safety and cost saving associated with the reuse of definitive circular external fixator components in a resource constrained environment. Method: We performed a retrospective review of all adult patients who were treated with either new or reused circular external fixators from a single manufacturer between January and December 2017. Reused circular external fixator components, excluding half pins and wires, were subjected to an in-house reprocessing protocol. Cost savings were calculated as the difference between the price of a completely new frame and the amount invoiced for new components only in a reused frame. Results: 33 patients were included in the study with an average age of 31.9 years. The mean duration of treatment with a circular external fixator was 5.8 months. No mechanical failure events were recorded during the study period. Our institution saved approximately 52% (R717 503.89) and 63 % (R136 568.19) of expected total cost for hexapod and Ilizarov frames respectively. Conclusion: The strategy of reusing circular external fixator components is unconventional and this study was conducted to evaluate the safety and potential savings in a resource constrained environment. We demonstrated this practice to be reasonably safe and to result in significant cost savings which might be relevant in low-and-middle income countries (LMICs).
Degree
thesis:*- Grantor
- Division of General Surgery
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Chironga, Kudzai
- Advisor dc:contributor.advisor
-
- Laubscher, Maritz
Subjects
dc:subject × 1Rights
- Language dc:language.rfc3066
- eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Chironga, K. (2022). <i>The Reuse of Circular External Fixator Components: An Assessment of Safety and Potential Savings</i>. (). ,Faculty of Health Sciences ,Division of General Surgery. Retrieved from http://hdl.handle.net/11427/37090
- Dc Identifier Chicagocitation
- Chironga, Kudzai. <i>"The Reuse of Circular External Fixator Components: An Assessment of Safety and Potential Savings."</i> ., ,Faculty of Health Sciences ,Division of General Surgery, 2022. http://hdl.handle.net/11427/37090
- Dc Identifier Citation
- Chironga, K. 2022. The Reuse of Circular External Fixator Components: An Assessment of Safety and Potential Savings. . ,Faculty of Health Sciences ,Division of General Surgery. http://hdl.handle.net/11427/37090
- Dc Identifier Ris
- TY - Master Thesis AU - Chironga, Kudzai AB - Purpose: Cost saving strategies are important especially in a resource constrained environment. One such strategy well supported in literature is the reuse of temporary monolateral external fixator components, a strategy we utilize at our institution. The aim of the study was to determine the safety and cost saving associated with the reuse of definitive circular external fixator components in a resource constrained environment. Method: We performed a retrospective review of all adult patients who were treated with either new or reused circular external fixators from a single manufacturer between January and December 2017. Reused circular external fixator components, excluding half pins and wires, were subjected to an in-house reprocessing protocol. Cost savings were calculated as the difference between the price of a completely new frame and the amount invoiced for new components only in a reused frame. Results: 33 patients were included in the study with an average age of 31.9 years. The mean duration of treatment with a circular external fixator was 5.8 months. No mechanical failure events were recorded during the study period. Our institution saved approximately 52% (R717 503.89) and 63 % (R136 568.19) of expected total cost for hexapod and Ilizarov frames respectively. Conclusion: The strategy of reusing circular external fixator components is unconventional and this study was conducted to evaluate the safety and potential savings in a resource constrained environment. We demonstrated this practice to be reasonably safe and to result in significant cost savings which might be relevant in low-and-middle income countries (LMICs). DA - 2022_ DB - OpenUCT DP - University of Cape Town KW - Orthopaedic Surgery LK - https://open.uct.ac.za PY - 2022 T1 - The Reuse of Circular External Fixator Components: An Assessment of Safety and Potential Savings TI - The Reuse of Circular External Fixator Components: An Assessment of Safety and Potential Savings UR - http://hdl.handle.net/11427/37090 ER -
- Dc Identifier Vancouvercitation
- Chironga K. The Reuse of Circular External Fixator Components: An Assessment of Safety and Potential Savings. []. ,Faculty of Health Sciences ,Division of General Surgery, 2022 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/37090