Back to search

Department of Computer Science

Distortion Correction in LODOX StatScan X-Ray Images

Abstract

dc:description.abstract

This thesis presents a background and description of a method of distortion correction in x-ray images produced by the LODOX StatScan machine. The distortion correction of an object's x-ray image is of particular interest in the medical field, particularly for prosthetics, implants, and orthopedic work. It is useful to be able to take accurate measurements directly from x-ray images and that these images should be obtained with a minimum of patient discomfort and exposure to radiation. Current x-ray images contain a non-linear distortion that must be corrected for by hand. This distortion is a result of the imaging process: X-rays from a point source spread out before being captured by a detection device such as a photographic plate or an electronic CCD sensor. Because of this, objects closer to the center of the detector suffer less distortion than those at the edges and makes the correction process a non-trivial task traditionally requiring multiple scans to be taken and stitched together manually to minimize the distortion. The method of distortion correction presented here is a novel approach to the problem using the LODOX StatScan machine. It uses multiple scans from the StatScan Machine to create a single completely distortion free image entirely automatically. This is a software based correction method. It takes multiple fan beam x-ray projections and uses them to create a single virtual parallel beam x-ray image suitable for making accurate measurements with.

Degree

thesis:*
Grantor
Department of Computer Science
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Beets, Matthew Paul

Subjects

dc:subject × 1

Rights

Language dc:language.rfc3066
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Beets, M. P. (2007). <i>Distortion Correction in LODOX StatScan X-Ray Images</i>. (). ,Faculty of Science ,Department of Computer Science. Retrieved from http://hdl.handle.net/11427/39173
Dc Identifier Chicagocitation
Beets, Matthew Paul. <i>"Distortion Correction in LODOX StatScan X-Ray Images."</i> ., ,Faculty of Science ,Department of Computer Science, 2007. http://hdl.handle.net/11427/39173
Dc Identifier Citation
Beets, M.P. 2007. Distortion Correction in LODOX StatScan X-Ray Images. . ,Faculty of Science ,Department of Computer Science. http://hdl.handle.net/11427/39173
Dc Identifier Ris
TY - Thesis / Dissertation AU - Beets, Matthew Paul AB - This thesis presents a background and description of a method of distortion correction in x-ray images produced by the LODOX StatScan machine. The distortion correction of an object's x-ray image is of particular interest in the medical field, particularly for prosthetics, implants, and orthopedic work. It is useful to be able to take accurate measurements directly from x-ray images and that these images should be obtained with a minimum of patient discomfort and exposure to radiation. Current x-ray images contain a non-linear distortion that must be corrected for by hand. This distortion is a result of the imaging process: X-rays from a point source spread out before being captured by a detection device such as a photographic plate or an electronic CCD sensor. Because of this, objects closer to the center of the detector suffer less distortion than those at the edges and makes the correction process a non-trivial task traditionally requiring multiple scans to be taken and stitched together manually to minimize the distortion. The method of distortion correction presented here is a novel approach to the problem using the LODOX StatScan machine. It uses multiple scans from the StatScan Machine to create a single completely distortion free image entirely automatically. This is a software based correction method. It takes multiple fan beam x-ray projections and uses them to create a single virtual parallel beam x-ray image suitable for making accurate measurements with. DA - 2007 DB - OpenUCT DP - University of Cape Town KW - Computer Science LK - https://open.uct.ac.za PY - 2007 T1 - Distortion Correction in LODOX StatScan X-Ray Images TI - Distortion Correction in LODOX StatScan X-Ray Images UR - http://hdl.handle.net/11427/39173 ER -
Dc Identifier Vancouvercitation
Beets MP. Distortion Correction in LODOX StatScan X-Ray Images. []. ,Faculty of Science ,Department of Computer Science, 2007 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/39173

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Beets, Matthew Paul. Distortion Correction in LODOX StatScan X-Ray Images. Department of Computer Science, 2007. https://hdl.handle.net/11427/39173