Back to search

Department of Electrical Engineering

Computer simulation programs to systematically screen protective relay applications for electric power distribution

Abstract

dc:description.abstract

[Pages 28,52,G:24,G:48 missing] Using EMTDC, an advanced closed-loop simulator, a set of network application tests is created in COMTRADE file format. The COMTRADE files created may be used to control an injection set or sets, which, in-turn, automatically inject protective devices. Part of the aim of the research has been to standardise the application tests, so that the testing of each device does not require a large number of calculated settings. The set of application tests simulate various network configurations, faults, loads, sources and devices. The tests are designed to highlight limitations within the protective schemes or their application within real networks. These limitations may take the form of incorrect settings and/or masking to certain applications. The application tests do in no way seek to supersede the necessity for qualification and/or acceptance testing. The tests are repeatable on any number of protective schemes and are independent of the test engineer. Although the test engineer is required to calculate and apply settings to the device being tested and to set up the test facility correctly, he/she cannot alter the test program in any way. In this way, protective devices are screened in a scientific manner to reveal their limitations in certain applications. A simulated nominal network model is developed by using a real network with its connected plant as the basis for the simulation model input data.

Degree

thesis:*
Grantor
Department of Electrical Engineering
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Craib, Andrew Murray Alexander
Advisor dc:contributor.advisor
  • Folly, Komla

Subjects

dc:subject × 1

Rights

Language dc:language.rfc3066
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Craib, A. M. A. (2006). <i>Computer simulation programs to systematically screen protective relay applications for electric power distribution</i>. (). ,Faculty of Engineering and the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/39986
Dc Identifier Chicagocitation
Craib, Andrew Murray Alexander. <i>"Computer simulation programs to systematically screen protective relay applications for electric power distribution."</i> ., ,Faculty of Engineering and the Built Environment ,Department of Electrical Engineering, 2006. http://hdl.handle.net/11427/39986
Dc Identifier Citation
Craib, A.M.A. 2006. Computer simulation programs to systematically screen protective relay applications for electric power distribution. . ,Faculty of Engineering and the Built Environment ,Department of Electrical Engineering. http://hdl.handle.net/11427/39986
Dc Identifier Ris
TY - Thesis / Dissertation AU - Craib, Andrew Murray Alexander AB - [Pages 28,52,G:24,G:48 missing] Using EMTDC, an advanced closed-loop simulator, a set of network application tests is created in COMTRADE file format. The COMTRADE files created may be used to control an injection set or sets, which, in-turn, automatically inject protective devices. Part of the aim of the research has been to standardise the application tests, so that the testing of each device does not require a large number of calculated settings. The set of application tests simulate various network configurations, faults, loads, sources and devices. The tests are designed to highlight limitations within the protective schemes or their application within real networks. These limitations may take the form of incorrect settings and/or masking to certain applications. The application tests do in no way seek to supersede the necessity for qualification and/or acceptance testing. The tests are repeatable on any number of protective schemes and are independent of the test engineer. Although the test engineer is required to calculate and apply settings to the device being tested and to set up the test facility correctly, he/she cannot alter the test program in any way. In this way, protective devices are screened in a scientific manner to reveal their limitations in certain applications. A simulated nominal network model is developed by using a real network with its connected plant as the basis for the simulation model input data. DA - 2006 DB - OpenUCT DP - University of Cape Town KW - Electrical Engineering LK - https://open.uct.ac.za PY - 2006 T1 - Computer simulation programs to systematically screen protective relay applications for electric power distribution TI - Computer simulation programs to systematically screen protective relay applications for electric power distribution UR - http://hdl.handle.net/11427/39986 ER -
Dc Identifier Vancouvercitation
Craib AMA. Computer simulation programs to systematically screen protective relay applications for electric power distribution. []. ,Faculty of Engineering and the Built Environment ,Department of Electrical Engineering, 2006 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/39986

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Craib, Andrew Murray Alexander. Computer simulation programs to systematically screen protective relay applications for electric power distribution. Department of Electrical Engineering, 2006. https://hdl.handle.net/11427/39986