Abstract
dc:description.abstractProton therapy is a form of radiation therapy where the patient is treated using abeam of high energy protons. The protons enter the patient and slow down, eventually stopping and dropping most of their energy within a certain depth due to Coulomb interactions between the protons and the electrons within the patient. The depth of the dose deposition, called the Bragg peak, is set by the initial energy of the proton beam, where higher energy protons will travel further than lower energy protons. Once a treatment is under way it is beneficial to monitor the position of the dose deposition within the patient in case the positioning of the beam is miscalculated, and the dose is not delivered to the cancerous area but instead to healthy tissue. Prompt Gamma Imaging (PGI) is a technique that has been developed to reconstruct the dose deposition, using a Compton Camera (CC). PGI uses the prompt ys produced by inelastic scatters between the proton beam and nuclei within the target. These y rays are detected using a detector capable of recording the position of two or more Compton scattering events within the detector crystals. For this work, PolarisM400 detectors were used which have four 20 x 20 x 10 mm Cadmium Zinc Telluride (CZT) crystals with a resolution of 11 x 11 pixels across each crystal face as well as depth sensitivity. PGI then uses the scattering positions within the detector to reconstruct a cone on whose surface the prompt y originated. There are various reconstruction algorithms that can combine these cones into an image which shows the likelihood of where the prompt ys originated from. Unfortunately, PGI has its drawbacks in a treatment scenario as the signal to noise ratio is low along with treatment intervals being too short to get statistically significant amounts of data. This thesis proposes a new approach to combine Positron Emission Particle Tracking (PEPT) along with PGI in a technique called PEPGI. Two 511 keV coincidence y rays, produced when positrons along the beam line annihilate with an electron, are detected within two detectors on either side of the target. The position of the beam line is located using the Birmingham algorithm. PEPT has been done successfully using a previous model of Polaris detectors and shown to locate a tracer with sub-millimeter precision. Different variables have been investigated for their effect on beam line locating, such as the distance of the detectors from the beam and the ability of the algorithm to detect the beam when it is not located along the z-axis. These investigations make use of the Geant4 simulation toolkit, which produces Monte Carlo simulations of the proton beam, target and detectors. These simulations are a cost effective and insightful method of benchmarking new techniques. Once the position of the beam line has been determined, a distance of closest approach (DCA) filter can be used to remove cones whose surfaces do not come within a prescribed distance to the beam line. This step has been proposed to improve the quality of data being used for image reconstruction. The filtered data can then be used for PGI reconstruction using the OCTANE EM2 algorithm within the CORE reconstruction toolkit. This work focuses on determining if the addition of the DCA filter does in fact improve image quality. This is done by removing the off-beam cones, running the reconstruction and comparing the results to PGI reconstructions that do not use the DCA filter. This shows the advantages of the PEPGI process to improve PGI dose reconstruction, and progress towards producing a clinically viable dose verification system for proton therapy.
Degree
thesis:*- Grantor dc:publisher.institution
- Department of Physics
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Roux, Alice
- Advisor dc:contributor.advisor
-
- Peterson, Steve
Subjects
dc:subject × 2Rights
- Language dc:language.iso
- en, eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Roux, A. (2026). <i>Positron enhanced prompt gamma imaging</i>. (). University of Cape Town ,Faculty of Science ,Department of Physics. Retrieved from http://hdl.handle.net/11427/43843
- Dc Identifier Chicagocitation
- Roux, Alice. <i>"Positron enhanced prompt gamma imaging."</i> ., University of Cape Town ,Faculty of Science ,Department of Physics, 2026. http://hdl.handle.net/11427/43843
- Dc Identifier Citation
- Roux, A. 2026. Positron enhanced prompt gamma imaging. . University of Cape Town ,Faculty of Science ,Department of Physics. http://hdl.handle.net/11427/43843
- Dc Identifier Ris
- TY - Thesis / Dissertation AU - Roux, Alice AB - Proton therapy is a form of radiation therapy where the patient is treated using abeam of high energy protons. The protons enter the patient and slow down, eventually stopping and dropping most of their energy within a certain depth due to Coulomb interactions between the protons and the electrons within the patient. The depth of the dose deposition, called the Bragg peak, is set by the initial energy of the proton beam, where higher energy protons will travel further than lower energy protons. Once a treatment is under way it is beneficial to monitor the position of the dose deposition within the patient in case the positioning of the beam is miscalculated, and the dose is not delivered to the cancerous area but instead to healthy tissue. Prompt Gamma Imaging (PGI) is a technique that has been developed to reconstruct the dose deposition, using a Compton Camera (CC). PGI uses the prompt ys produced by inelastic scatters between the proton beam and nuclei within the target. These y rays are detected using a detector capable of recording the position of two or more Compton scattering events within the detector crystals. For this work, PolarisM400 detectors were used which have four 20 x 20 x 10 mm Cadmium Zinc Telluride (CZT) crystals with a resolution of 11 x 11 pixels across each crystal face as well as depth sensitivity. PGI then uses the scattering positions within the detector to reconstruct a cone on whose surface the prompt y originated. There are various reconstruction algorithms that can combine these cones into an image which shows the likelihood of where the prompt ys originated from. Unfortunately, PGI has its drawbacks in a treatment scenario as the signal to noise ratio is low along with treatment intervals being too short to get statistically significant amounts of data. This thesis proposes a new approach to combine Positron Emission Particle Tracking (PEPT) along with PGI in a technique called PEPGI. Two 511 keV coincidence y rays, produced when positrons along the beam line annihilate with an electron, are detected within two detectors on either side of the target. The position of the beam line is located using the Birmingham algorithm. PEPT has been done successfully using a previous model of Polaris detectors and shown to locate a tracer with sub-millimeter precision. Different variables have been investigated for their effect on beam line locating, such as the distance of the detectors from the beam and the ability of the algorithm to detect the beam when it is not located along the z-axis. These investigations make use of the Geant4 simulation toolkit, which produces Monte Carlo simulations of the proton beam, target and detectors. These simulations are a cost effective and insightful method of benchmarking new techniques. Once the position of the beam line has been determined, a distance of closest approach (DCA) filter can be used to remove cones whose surfaces do not come within a prescribed distance to the beam line. This step has been proposed to improve the quality of data being used for image reconstruction. The filtered data can then be used for PGI reconstruction using the OCTANE EM2 algorithm within the CORE reconstruction toolkit. This work focuses on determining if the addition of the DCA filter does in fact improve image quality. This is done by removing the off-beam cones, running the reconstruction and comparing the results to PGI reconstructions that do not use the DCA filter. This shows the advantages of the PEPGI process to improve PGI dose reconstruction, and progress towards producing a clinically viable dose verification system for proton therapy. DA - 2026 DB - OpenUCT DP - University of Cape Town KW - proton therapy KW - gamma imaging LK - https://open.uct.ac.za PB - University of Cape Town PY - 2026 T1 - Positron enhanced prompt gamma imaging TI - Positron enhanced prompt gamma imaging UR - http://hdl.handle.net/11427/43843 ER -
- Dc Identifier Vancouvercitation
- Roux A. Positron enhanced prompt gamma imaging. []. University of Cape Town ,Faculty of Science ,Department of Physics, 2026 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/43843