Back to search

Department of Medicine

Development and Validation of Analytical Assays for Measuring Cannabinoids in Cannabis-Based Products

Abstract

dc:description.abstract

Cannabis has long been used as a source of fibre, food, oil, and medicine, and is now commonly available in oils, tinctures, capsules, and infused food products. Studies have supported the therapeutic benefits of cannabis, demonstrating analgesic, anti-inflammatory, and antiemetic effects, which are attributed to biologically active compounds such as cannabinoids. Over 100 cannabinoids have been identified in cannabis, with six being the most extensively studied. These major cannabinoids are frequently incorporated into ingestible products for both medicinal and recreational use. With increasing awareness of the pharmacological potential of cannabis-based products and the widespread legalisation of their use, the need for harmonised global quality standards has become urgent. Accurate determination of cannabinoid profiles and concentrations is essential to ensure that products are prescribed and used safely and effectively. However, the lack of standardised manufacturing practices often leads to significant variability in cannabinoid content. Therefore, the determination and monitoring of the cannabinoids in cannabis-based products is essential. A robust and novel method was developed and validated for the quantification of six major cannabinoids in oil, namely cannabichromene, cannabidiol, cannabigerol, cannabinol, 9-tetrahydrocannabinol, and tetrahydrocannabivarin. In addition, a separate novel method was developed to assess the purity of cannabis-based products. Analyses were performed following appropriate sample dilution, employing high-performance liquid chromatography coupled with tandem mass spectrometry for quantification, and diode array detection for purity assessment. All analytes were chromatographically separated using gradient elution on a Poroshell 120 EC-C18 analytical column (2.1 mm x 150 mm, 2.7 μm), with mobile phases consisting of 0.1% formic acid in a mixture of water and acetonitrile (60:40, v/v) and 0.1% formic acid in a mixture of acetonitrile and methanol (80:20, v/v). The total run time was 20 minutes. For analyte quantification, a Sciex API 3200 mass spectrometer operating at unit resolution in multiple reaction monitoring mode with electrospray ionisation was used. Purity analysis was performed using high-performance liquid chromatography coupled with diode array detection to measure sample absorbance over the 200-600 nm spectral scan range. Accuracy and precision were confirmed across three consecutive, independent runs. The calibration curve fits a quadratic regression (weighted by 1/x) over the range of 125–4000 μg/mL for all analytes in oil. The method was reproducible for all analytes across oils from six different sources and was unaffected by matrix effects, with a mean regression precision (CV(%)) between 3.0 and 5.1%. The average process efficiency ranged from 99.8% to 102.5%, with a CV(%) of 0.4% to 4.3%. The method was selective for all the analytes, with no interfering peaks and no significant autosampler carryover observed. The method showed sufficient sensitivity to reliably distinguish analyte peaks from background noise at the lower limit of quantification. Long-term matrix stability was confirmed for five of the six analytes for up to 32 days at 4°C in two authentic oil products. Results for cannabigerol were inconclusive as one authentic product met the acceptance criteria while the other did not, likely due to formulation differences between the products. Temperature stability was also demonstrated for the same five analytes at room temperature and 30°C; however, definitive confirmation of cannabigerol stability was not possible, as the reference used for this assessment was long-term matrix stability data that were considered unreliable and therefore not reportable. Based on these findings and label recommendations, all oil products should be stored at room temperature (up to ~30°C). All analytes were shown to be stable in the isopropanol-containing matrix at room temperature under sodium vapour light for at least 4 hours. Additionally, all analytes in the prepared samples remained stable in the autosampler for at least 94 hours at ~8°C. Lastly, reinjection reproducibility and autosampler stability results indicate that batches can be partially or fully reinjected within this 94-hour period without compromising data integrity. For purity analysis, the developed method utilising diode array detection yielded well-resolved analyte peaks, stable retention times, and negligible carryover, with multi-wavelength spectra confirming peak identity and impurity profiles. Both methods were successfully applied to commercially available products. The analyses showed that some products aligned with their labelled concentrations and purity, while many exhibited significant discrepancies and variable impurity levels, indicating inconsistent quality and labelling accuracy.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Medicine
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bernard, Rizqah
Advisors dc:contributor.advisor
  • Wiesner, Lubbe
  • Castel, Sandra
  • Joubert, Anton

Subjects

dc:subject × 2

Rights

Language dc:language.iso
en, eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Bernard, R. (2026). <i>Development and Validation of Analytical Assays for Measuring Cannabinoids in Cannabis-Based Products</i>. (). University of Cape Town ,Faculty of Health Sciences ,Department of Medicine. Retrieved from http://hdl.handle.net/11427/43949
Dc Identifier Chicagocitation
Bernard, Rizqah. <i>"Development and Validation of Analytical Assays for Measuring Cannabinoids in Cannabis-Based Products."</i> ., University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2026. http://hdl.handle.net/11427/43949
Dc Identifier Citation
Bernard, R. 2026. Development and Validation of Analytical Assays for Measuring Cannabinoids in Cannabis-Based Products. . University of Cape Town ,Faculty of Health Sciences ,Department of Medicine. http://hdl.handle.net/11427/43949
Dc Identifier Ris
TY - Thesis / Dissertation AU - Bernard, Rizqah AB - Cannabis has long been used as a source of fibre, food, oil, and medicine, and is now commonly available in oils, tinctures, capsules, and infused food products. Studies have supported the therapeutic benefits of cannabis, demonstrating analgesic, anti-inflammatory, and antiemetic effects, which are attributed to biologically active compounds such as cannabinoids. Over 100 cannabinoids have been identified in cannabis, with six being the most extensively studied. These major cannabinoids are frequently incorporated into ingestible products for both medicinal and recreational use. With increasing awareness of the pharmacological potential of cannabis-based products and the widespread legalisation of their use, the need for harmonised global quality standards has become urgent. Accurate determination of cannabinoid profiles and concentrations is essential to ensure that products are prescribed and used safely and effectively. However, the lack of standardised manufacturing practices often leads to significant variability in cannabinoid content. Therefore, the determination and monitoring of the cannabinoids in cannabis-based products is essential. A robust and novel method was developed and validated for the quantification of six major cannabinoids in oil, namely cannabichromene, cannabidiol, cannabigerol, cannabinol, 9-tetrahydrocannabinol, and tetrahydrocannabivarin. In addition, a separate novel method was developed to assess the purity of cannabis-based products. Analyses were performed following appropriate sample dilution, employing high-performance liquid chromatography coupled with tandem mass spectrometry for quantification, and diode array detection for purity assessment. All analytes were chromatographically separated using gradient elution on a Poroshell 120 EC-C18 analytical column (2.1 mm x 150 mm, 2.7 μm), with mobile phases consisting of 0.1% formic acid in a mixture of water and acetonitrile (60:40, v/v) and 0.1% formic acid in a mixture of acetonitrile and methanol (80:20, v/v). The total run time was 20 minutes. For analyte quantification, a Sciex API 3200 mass spectrometer operating at unit resolution in multiple reaction monitoring mode with electrospray ionisation was used. Purity analysis was performed using high-performance liquid chromatography coupled with diode array detection to measure sample absorbance over the 200-600 nm spectral scan range. Accuracy and precision were confirmed across three consecutive, independent runs. The calibration curve fits a quadratic regression (weighted by 1/x) over the range of 125–4000 μg/mL for all analytes in oil. The method was reproducible for all analytes across oils from six different sources and was unaffected by matrix effects, with a mean regression precision (CV(%)) between 3.0 and 5.1%. The average process efficiency ranged from 99.8% to 102.5%, with a CV(%) of 0.4% to 4.3%. The method was selective for all the analytes, with no interfering peaks and no significant autosampler carryover observed. The method showed sufficient sensitivity to reliably distinguish analyte peaks from background noise at the lower limit of quantification. Long-term matrix stability was confirmed for five of the six analytes for up to 32 days at 4°C in two authentic oil products. Results for cannabigerol were inconclusive as one authentic product met the acceptance criteria while the other did not, likely due to formulation differences between the products. Temperature stability was also demonstrated for the same five analytes at room temperature and 30°C; however, definitive confirmation of cannabigerol stability was not possible, as the reference used for this assessment was long-term matrix stability data that were considered unreliable and therefore not reportable. Based on these findings and label recommendations, all oil products should be stored at room temperature (up to ~30°C). All analytes were shown to be stable in the isopropanol-containing matrix at room temperature under sodium vapour light for at least 4 hours. Additionally, all analytes in the prepared samples remained stable in the autosampler for at least 94 hours at ~8°C. Lastly, reinjection reproducibility and autosampler stability results indicate that batches can be partially or fully reinjected within this 94-hour period without compromising data integrity. For purity analysis, the developed method utilising diode array detection yielded well-resolved analyte peaks, stable retention times, and negligible carryover, with multi-wavelength spectra confirming peak identity and impurity profiles. Both methods were successfully applied to commercially available products. The analyses showed that some products aligned with their labelled concentrations and purity, while many exhibited significant discrepancies and variable impurity levels, indicating inconsistent quality and labelling accuracy. DA - 2026 DB - OpenUCT DP - University of Cape Town KW - cannabis KW - cannabinoids LK - https://open.uct.ac.za PB - University of Cape Town PY - 2026 T1 - Development and Validation of Analytical Assays for Measuring Cannabinoids in Cannabis-Based Products TI - Development and Validation of Analytical Assays for Measuring Cannabinoids in Cannabis-Based Products UR - http://hdl.handle.net/11427/43949 ER -
Dc Identifier Vancouvercitation
Bernard R. Development and Validation of Analytical Assays for Measuring Cannabinoids in Cannabis-Based Products. []. University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2026 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/43949

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-25
Source record
OAI-PMH GetRecord
citation

Bernard, Rizqah. Development and Validation of Analytical Assays for Measuring Cannabinoids in Cannabis-Based Products. Department of Medicine, 2026. https://hdl.handle.net/11427/43949