Back to search

Department of Electrical Engineering

Load compensation : design of a real time analysis and control device

Abstract

dc:description.abstract

The aim of this thesis is to produce a load compensator for a three-phase system. It should be simple, accurate and affordable. The three-phase load compensator design is based on a more recent definition of power factor. Attempts to establish a universally acceptable definition can be traced as early as 1920 at the 36th Annual convention of the American Institution of Electrical Engineers. Subsequently, a number of definitions have been adopted by different scholars. Each definition can lead to a different compensator solution. This problem, for example, is illustrated by Eammanuel [25].

Degree

thesis:*
Grantor dc:publisher.institution
Department of Electrical Engineering
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sebitosi, A B
Advisor dc:contributor.advisor
  • Malengret, Michel

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Sebitosi, A. B. (2001). <i>Load compensation : design of a real time analysis and control device</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/5107
Dc Identifier Chicagocitation
Sebitosi, A B. <i>"Load compensation : design of a real time analysis and control device."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001. http://hdl.handle.net/11427/5107
Dc Identifier Citation
Sebitosi, A. 2001. Load compensation : design of a real time analysis and control device. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Sebitosi, A B AB - The aim of this thesis is to produce a load compensator for a three-phase system. It should be simple, accurate and affordable. The three-phase load compensator design is based on a more recent definition of power factor. Attempts to establish a universally acceptable definition can be traced as early as 1920 at the 36th Annual convention of the American Institution of Electrical Engineers. Subsequently, a number of definitions have been adopted by different scholars. Each definition can lead to a different compensator solution. This problem, for example, is illustrated by Eammanuel [25]. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - Load compensation : design of a real time analysis and control device TI - Load compensation : design of a real time analysis and control device UR - http://hdl.handle.net/11427/5107 ER -
Dc Identifier Vancouvercitation
Sebitosi AB. Load compensation : design of a real time analysis and control device. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/5107

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-25
Source record
OAI-PMH GetRecord
citation

Sebitosi, A B. Load compensation : design of a real time analysis and control device. Department of Electrical Engineering, 2001. https://hdl.handle.net/11427/5107