Department of Mechanical Engineering
The design and testing of a constrained proximal humeral total shoulder replacement (TSR)
Abstract
dc:description.abstractOrthopedic oncology provides for a challenging field in prosthetic design, especially in proximal humeral sarcoma cases. In these cases a large volume of bone an muscle is removed as a result of the sarcoma. This leaves insufficient musculature to stabilize an un-constrained prosthesis. This report deals with the design and testing of constrained total shoulder replacements, as their inherent built-in stability compensates for lost musculature stability. The weakest area of any shoulder replacement is the fixation of the glenoid component to the scapula. The design of an innovative glenoidal attachment system was the main focus of the project.
Degree
thesis:*- Grantor dc:publisher.institution
- Department of Mechanical Engineering
- Year dc:date.issued
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wessels, Gregory D
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Wessels, G. D. (2005). <i>The design and testing of a constrained proximal humeral total shoulder replacement (TSR)</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering. Retrieved from http://hdl.handle.net/11427/5453
- Dc Identifier Chicagocitation
- Wessels, Gregory D. <i>"The design and testing of a constrained proximal humeral total shoulder replacement (TSR)."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering, 2005. http://hdl.handle.net/11427/5453
- Dc Identifier Citation
- Wessels, G. 2005. The design and testing of a constrained proximal humeral total shoulder replacement (TSR). University of Cape Town.
- Dc Identifier Ris
- TY - Thesis / Dissertation AU - Wessels, Gregory D AB - Orthopedic oncology provides for a challenging field in prosthetic design, especially in proximal humeral sarcoma cases. In these cases a large volume of bone an muscle is removed as a result of the sarcoma. This leaves insufficient musculature to stabilize an un-constrained prosthesis. This report deals with the design and testing of constrained total shoulder replacements, as their inherent built-in stability compensates for lost musculature stability. The weakest area of any shoulder replacement is the fixation of the glenoid component to the scapula. The design of an innovative glenoidal attachment system was the main focus of the project. DA - 2005 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2005 T1 - The design and testing of a constrained proximal humeral total shoulder replacement (TSR) TI - The design and testing of a constrained proximal humeral total shoulder replacement (TSR) UR - http://hdl.handle.net/11427/5453 ER -
- Dc Identifier Vancouvercitation
- Wessels GD. The design and testing of a constrained proximal humeral total shoulder replacement (TSR). [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering, 2005 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/5453