Back to search

Department of Civil Engineering

The effect of the type, size, position and recycle ratio of the anoxic zone on low F/M filament bulking in nitrogen removal activated sludge systems

Abstract

dc:description.abstract

Filamentous bulking, which causes deterioration in sludge settleability has been shown, in two nation-wide surveys to be a problem of considerable proportions. Poor sludge settleability in the secondary clarifier limits the daily flow and load that can be treated in activated sludge wastewater treatment plants. Controlling sludge settleability to relatively low levels i.e. Diluted Sludge Volume Index (DSVI < 100 rnl/g) by controlling filamentous organism proliferation would allow increased daily flow and loads by up to 100 on existing activated sludge wastewater treatment plants. From the two surveys, Blackbeard et al. (1986,1988) found that mainly six filamentous organisms tended to dominate in activated sludges in N and N&P removal plants i.e. types 0092, 0041, 0675, 1851, 0914 and Microthrix parvicella. Four of these six filaments are classified by Jenkins et al (1984) as low Food/Micro-organism (low F/M) filaments. At the University of Cape Town and in a 4 year research programme (1986 to 1989) Gabb et al (1989a) investigated specific methods to control low F /M filament proliferation. Traditionally the promoted specific bulking control method was inclusion of either an anoxic or aerobic selector at the head of the wastewater treatment plant. Gabb et al (1989a) found that selectors did not control low F/M filament proliferation but that continuous aeration did. They concluded that the presence of anoxic and aerobic zones in a treatment plant was an important factor in low F/M filament proliferation. In 1989 a second research programme was initiated at the University of Cape Town to identify the factors that influence low F/M filament proliferation. Completed research thus far has established inter alia that fully anoxic and fully aerobic conditions successfully control low F/M filament proliferation but that alternating anoxic-aerobic conditions in single reactor intermittent aeration systems promoted proliferation. The research presented in this thesis focuses on the interchange between anoxic and aerobic conditions in nitrogen removal systems and its effect on low F/M filament proliferation.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Civil Engineering
Year dc:date.issued
1992

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hulsman, Andrew Charles
Advisor dc:contributor.advisor
  • Ekama, George A

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Hulsman, A. C. (1992). <i>The effect of the type, size, position and recycle ratio of the anoxic zone on low F/M filament bulking in nitrogen removal activated sludge systems</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Civil Engineering. Retrieved from http://hdl.handle.net/11427/8302
Dc Identifier Chicagocitation
Hulsman, Andrew Charles. <i>"The effect of the type, size, position and recycle ratio of the anoxic zone on low F/M filament bulking in nitrogen removal activated sludge systems."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Civil Engineering, 1992. http://hdl.handle.net/11427/8302
Dc Identifier Citation
Hulsman, A. 1992. The effect of the type, size, position and recycle ratio of the anoxic zone on low F/M filament bulking in nitrogen removal activated sludge systems. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Hulsman, Andrew Charles AB - Filamentous bulking, which causes deterioration in sludge settleability has been shown, in two nation-wide surveys to be a problem of considerable proportions. Poor sludge settleability in the secondary clarifier limits the daily flow and load that can be treated in activated sludge wastewater treatment plants. Controlling sludge settleability to relatively low levels i.e. Diluted Sludge Volume Index (DSVI < 100 rnl/g) by controlling filamentous organism proliferation would allow increased daily flow and loads by up to 100 on existing activated sludge wastewater treatment plants. From the two surveys, Blackbeard et al. (1986,1988) found that mainly six filamentous organisms tended to dominate in activated sludges in N and N&P removal plants i.e. types 0092, 0041, 0675, 1851, 0914 and Microthrix parvicella. Four of these six filaments are classified by Jenkins et al (1984) as low Food/Micro-organism (low F/M) filaments. At the University of Cape Town and in a 4 year research programme (1986 to 1989) Gabb et al (1989a) investigated specific methods to control low F /M filament proliferation. Traditionally the promoted specific bulking control method was inclusion of either an anoxic or aerobic selector at the head of the wastewater treatment plant. Gabb et al (1989a) found that selectors did not control low F/M filament proliferation but that continuous aeration did. They concluded that the presence of anoxic and aerobic zones in a treatment plant was an important factor in low F/M filament proliferation. In 1989 a second research programme was initiated at the University of Cape Town to identify the factors that influence low F/M filament proliferation. Completed research thus far has established inter alia that fully anoxic and fully aerobic conditions successfully control low F/M filament proliferation but that alternating anoxic-aerobic conditions in single reactor intermittent aeration systems promoted proliferation. The research presented in this thesis focuses on the interchange between anoxic and aerobic conditions in nitrogen removal systems and its effect on low F/M filament proliferation. DA - 1992 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 1992 T1 - The effect of the type, size, position and recycle ratio of the anoxic zone on low F/M filament bulking in nitrogen removal activated sludge systems TI - The effect of the type, size, position and recycle ratio of the anoxic zone on low F/M filament bulking in nitrogen removal activated sludge systems UR - http://hdl.handle.net/11427/8302 ER -
Dc Identifier Vancouvercitation
Hulsman AC. The effect of the type, size, position and recycle ratio of the anoxic zone on low F/M filament bulking in nitrogen removal activated sludge systems. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Civil Engineering, 1992 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/8302

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Hulsman, Andrew Charles. The effect of the type, size, position and recycle ratio of the anoxic zone on low F/M filament bulking in nitrogen removal activated sludge systems. Department of Civil Engineering, 1992. https://hdl.handle.net/11427/8302