Department of Chemical Engineering
The measurement and modelling of the intracrystalline diffusion of cyclohexane in ZSM-5 using zero length column chromatography
Abstract
dc:description.abstractZeolites are important solid acid catalysts largely because of their microporous nature giving them strong shape selective properties. This shape selectivity may be improved by depositing an inert (e. g. silaceous) layer on the surface of the catalyst crystals, which inertises non-shape selective surface acid sites and increases diffusional transport resistances. This thesis presents an investigation, using the zero length column (ZLC) method, into changes in the diffusional properties of cyclohexane in ZSM-5 that has had tetraethoxysilane deposited on the surface in the liquid phase. Theoretical analyses of the ZLC technique and its use in a detailed study of cyclohexane in unmodified ZSM-5 were performed in order to prove the reliability of the technique and measure baseline behaviour of the selected system. The ZLC method is a chromatographic technique for the measurement of diffusion coefficients in porous sorbents. Originally developed for gaseous hydrocarbon / zeolite powder systems, it has been experimentally extended to the measurement of liquid sorbate systems, macroporous zeolite pellets and resins and the measurement of self-diffusion through tracer exchange. The technique is robust against the intrusion of external heat and mass transfer effects by the use of relatively high flow rates and small catalyst samples, Analysis of the desorption curves is simple: the slope of the linear (on semilogarthmic axes) long time region gives the diffusional time constant. This so-called 'long time' analysis gives an accurate result for the diilusional time constant.
Degree
thesis:*- Grantor dc:publisher.institution
- Department of Chemical Engineering
- Year dc:date.issued
- 2001
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Duncan, Warwick
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Duncan, W. (2001). <i>The measurement and modelling of the intracrystalline diffusion of cyclohexane in ZSM-5 using zero length column chromatography</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Chemical Engineering. Retrieved from http://hdl.handle.net/11427/8743
- Dc Identifier Chicagocitation
- Duncan, Warwick. <i>"The measurement and modelling of the intracrystalline diffusion of cyclohexane in ZSM-5 using zero length column chromatography."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Chemical Engineering, 2001. http://hdl.handle.net/11427/8743
- Dc Identifier Citation
- Duncan, W. 2001. The measurement and modelling of the intracrystalline diffusion of cyclohexane in ZSM-5 using zero length column chromatography. University of Cape Town.
- Dc Identifier Ris
- TY - Thesis / Dissertation AU - Duncan, Warwick AB - Zeolites are important solid acid catalysts largely because of their microporous nature giving them strong shape selective properties. This shape selectivity may be improved by depositing an inert (e. g. silaceous) layer on the surface of the catalyst crystals, which inertises non-shape selective surface acid sites and increases diffusional transport resistances. This thesis presents an investigation, using the zero length column (ZLC) method, into changes in the diffusional properties of cyclohexane in ZSM-5 that has had tetraethoxysilane deposited on the surface in the liquid phase. Theoretical analyses of the ZLC technique and its use in a detailed study of cyclohexane in unmodified ZSM-5 were performed in order to prove the reliability of the technique and measure baseline behaviour of the selected system. The ZLC method is a chromatographic technique for the measurement of diffusion coefficients in porous sorbents. Originally developed for gaseous hydrocarbon / zeolite powder systems, it has been experimentally extended to the measurement of liquid sorbate systems, macroporous zeolite pellets and resins and the measurement of self-diffusion through tracer exchange. The technique is robust against the intrusion of external heat and mass transfer effects by the use of relatively high flow rates and small catalyst samples, Analysis of the desorption curves is simple: the slope of the linear (on semilogarthmic axes) long time region gives the diffusional time constant. This so-called 'long time' analysis gives an accurate result for the diilusional time constant. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - The measurement and modelling of the intracrystalline diffusion of cyclohexane in ZSM-5 using zero length column chromatography TI - The measurement and modelling of the intracrystalline diffusion of cyclohexane in ZSM-5 using zero length column chromatography UR - http://hdl.handle.net/11427/8743 ER -
- Dc Identifier Vancouvercitation
- Duncan W. The measurement and modelling of the intracrystalline diffusion of cyclohexane in ZSM-5 using zero length column chromatography. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Chemical Engineering, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/8743