Back to search

Department of Electrical Engineering

Application of evolutionary algorithms for optimal directional overcurrent relay coordination

Abstract

dc:description.abstract

Relay coordination is necessary to ensure that while protection relays operate as fast as possible, they are also able to isolate only the faulted parts of the system from the network, ensuring that a power system disturbance does not result in interruption of the power supply to a larger part of the power system network. Optimal relay coordination for overcurrent relays depends on two parameters, namely, Time Multiplier and Pickup Current Setting. The conventional method of setting these two parameters for overcurrent relays applied on the power system network is to first determine the main and backup relay pairs which form part of the clockwise and anti-clockwise loops around the power system network. The relays are then set through an iterative process to ensure coordination. Initially, a general rule of setting relays to operate in 0.2 seconds for faults in the primary zone, to ensure fast operation, and in 0.2 seconds plus additional grading time, to ensure coordination, for faults in the backup zone is applied. The next relay in the loop is tested to check if it fulfils the requirements of the initial general rule. If the conditions of the general rule are not met, the previous relay’s setting is adjusted to meet the requirements. This process is repeated until all the relays around the loop are set. Conventional relay coordination process has a limitation in the sense that it is deterministic and the settings of subsequent relays depend on the initial guess of the settings of the initial relay. Therefore, this method does not necessarily provide solutions which guarantee optimal relay coordination but the best of the solutions tried.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Electrical Engineering
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stenane, Ndabeni Moses
Advisor dc:contributor.advisor
  • Folly, Komla A

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Stenane, N. M. (2014). <i>Application of evolutionary algorithms for optimal directional overcurrent relay coordination</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/9092
Dc Identifier Chicagocitation
Stenane, Ndabeni Moses. <i>"Application of evolutionary algorithms for optimal directional overcurrent relay coordination."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2014. http://hdl.handle.net/11427/9092
Dc Identifier Citation
Stenane, N. 2014. Application of evolutionary algorithms for optimal directional overcurrent relay coordination. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Stenane, Ndabeni Moses AB - Relay coordination is necessary to ensure that while protection relays operate as fast as possible, they are also able to isolate only the faulted parts of the system from the network, ensuring that a power system disturbance does not result in interruption of the power supply to a larger part of the power system network. Optimal relay coordination for overcurrent relays depends on two parameters, namely, Time Multiplier and Pickup Current Setting. The conventional method of setting these two parameters for overcurrent relays applied on the power system network is to first determine the main and backup relay pairs which form part of the clockwise and anti-clockwise loops around the power system network. The relays are then set through an iterative process to ensure coordination. Initially, a general rule of setting relays to operate in 0.2 seconds for faults in the primary zone, to ensure fast operation, and in 0.2 seconds plus additional grading time, to ensure coordination, for faults in the backup zone is applied. The next relay in the loop is tested to check if it fulfils the requirements of the initial general rule. If the conditions of the general rule are not met, the previous relay’s setting is adjusted to meet the requirements. This process is repeated until all the relays around the loop are set. Conventional relay coordination process has a limitation in the sense that it is deterministic and the settings of subsequent relays depend on the initial guess of the settings of the initial relay. Therefore, this method does not necessarily provide solutions which guarantee optimal relay coordination but the best of the solutions tried. DA - 2014 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2014 T1 - Application of evolutionary algorithms for optimal directional overcurrent relay coordination TI - Application of evolutionary algorithms for optimal directional overcurrent relay coordination UR - http://hdl.handle.net/11427/9092 ER -
Dc Identifier Vancouvercitation
Stenane NM. Application of evolutionary algorithms for optimal directional overcurrent relay coordination. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2014 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/9092

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Stenane, Ndabeni Moses. Application of evolutionary algorithms for optimal directional overcurrent relay coordination. Department of Electrical Engineering, 2014. https://hdl.handle.net/11427/9092