Back to search

Carleton University

Monitoring the propagation of lung sounds using electronic stethoscope arrays

Abstract

dc:description.abstract

This thesis presents the design and prototype testing of a novel medical instrument designed to measure changes in to acoustic transmission properties of lung tissue. Since tissue acoustic transmission is largely determined by the distribution of lung fluid and lung tissue density, this instrument has potential applications for monitoring and diagnosis of patients with such obstructive lung diseases which are associated with accumulation of lung fluid and collapse of lung tissue. The apparatus consists of an array of 4 electronic stethoscopes linked together via a fully adjustable harness. A White Gaussian Noise (WGN) input sound is injected into the mouth via a modified speaker and measured on the surface of the chest using the array of stethoscopes. Data were analysed using the Normalized Least Mean Squares (NLMS) adaptive filtering algorithm to develop a transfer function based on the propagation characteristics of the injected signal. This transfer function is then analysed to determine the frequency response and the propagation delay at each stethoscope. The system was calibrated to account for delays in the signal acquisition equipment and verified using a chest phantom model. System non-linearites were analysed and determined to be sufficiently small to justify the linear model. Phantom test results show that as the volume of fluid in the lungs increases, the sound propagation delay decreases. In-vivo results were measured on healthy volunteers and show comparable results to the lung phantom with no volume of water injected and that the instrument can detect sound propagation delay variations with changes in posture. Based on these results, this instrument is able to measure parameters of the lungs including propagation delay and frequency/impulse responses, which show useful correspondence to known physiological changes.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (M.App.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Engineering, Biomedical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mulligan, Kyle R.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright © 2009 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mulligan, Kyle R.. Monitoring the propagation of lung sounds using electronic stethoscope arrays. Master's thesis, Carleton University, 2009. https://hdl.handle.net/20.500.14718/31874