Abstract
dc:description.abstractThis thesis studies the fire behaviour of Cross Laminated Timber (CLT) panels in partially protected rooms. A one-dimensional heat transfer model was developed to determine the fire resistance of CLT floor and wall panels. During this study, three room fire tests were conducted at Carleton University Fire Research Laboratory to determine the maximum percentage of unprotected CLT surface area that will yield similar results to that of a fully protected room. The rooms had a single opening and were constructed entirely using 3-ply, 105 mm thick CLT panels. A non-standard, parametric fire using furniture and clothing as fuel was used and 2 layers of gypsum board were used to cover the ceiling and the protected walls. The Heat Release Rate, temperature, charring rate and gypsum falloff time of each test was collected. The results obtained from the room test where then compared to the numerical heat transfer model.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science (M.App.Sc.)
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Engineering, Civil
- Grantor dc:publisher
- Carleton University
- Year dc:date.issued
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Medina Hevia, Alejandro Ramon
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Copyright © 2015 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
- Language dc:language.iso
- en