Back to search

Carleton University

Automation of the Cytokinesis-Block Micronucleus Assay Using Imaging Flow Cytometry for High Throughput Radiation Biodosimetry

Abstract

dc:description.abstract

The cytokinesis-block micronucleus (CBMN) assay is employed in biodosimetry to determine the dose of radiation to exposed individuals from the frequency of micronuclei (MN) in binucleated lymphocyte cells (BNCs). The assay is traditionally performed using a microscope-based scoring procedure which can be labour-intensive, time consuming and subject to variability of interpretation between scorers. This thesis investigates the feasibility of adapting the CBMN assay to an imaging flow cytometry method using the ImageStreamX (ISX) imaging flow cytometer and hypothesises that dose estimations can be obtained with adequate sensitivity for triage radiation biodosimetry. A protocol to perform the CBMN assay on the ISX along with a data analysis method using the Image Data Exploration and Analysis Software (IDEAS®) were developed. Using irradiated whole blood samples it was shown that the ISX-CBMN method could automatically image and enumerate BNCs and MN. Additionally, between 0-4 Gy the rate of MN per BNC follows a linear quadratic dependence with dose, similar to what is observed when performing the assay using traditional protocols. The ISX-CBMN method was then expanded into a multi-parameter radiation biodosimetry tool. Irradiated whole blood samples were analyzed using an optimized version of the IDEAS® analysis template which incorporated automated scoring of mononuclear cells (MNCs). Dose response calibration curves for the rate of MN per BNC, percentage of MNCs and the replication index (RI) were generated. Results indicated that this multi-parameter method may be able to provide dose estimations for individuals who have received a radiation dose of higher than 4 Gy. The traditional CBMN assay is limited by the large blood culture volume (500 µL - 2 mL) and the 72 h culture time. It was posited that the ISX-CBMN method could overcome both of these requirements and results showed that dose estimations could be generated to within 0.5 Gy of the delivered dose after only 48 h of culture time with an initial blood volume of 200 µL. The adaptation of the CBMN assay to an imaging flow cytometry method greatly increases its applicability in high throughput triage radiation biodosimetry.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rodrigues, Matthew

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright © 2015 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Rodrigues, Matthew. Automation of the Cytokinesis-Block Micronucleus Assay Using Imaging Flow Cytometry for High Throughput Radiation Biodosimetry. Doctoral thesis, Carleton University, 2015. https://hdl.handle.net/20.500.14718/32280