Back to search

Carleton University

An Iterative-Triple-Energy Window Approach to Cross-Talk Correction in Quantitative Small Animal Tc-99m and In-111 Single Photon Emission Computer Tomography

Abstract

dc:description.abstract

Dual isotope Single Photon Emission Computed Tomography permits in vivo measurements of two separate signals simultaneously, but the quantitative accuracy of these measurements is degraded due to the presence of cross-talk. An iterative triple energy window method was developed to correct for cross-talk in In-111 and Tc-99m dual isotope SPECT. The correction was evaluated in comparison to other TEW-based methods in phantoms and in vivo. In phantoms containing different (Tc-99m)/(In-111) activity fractions, scattered In-111 photons falsely detected as Tc-99m resulted in an over-estimation of Tc-99m activity by up to 80%. Application of the iterative TEW resulted in quantification of total Tc-99m activity within 5% of the truth across the largest range of activity fractions. In vivo, modified and iterative TEW both quantified total heart Tc-99m activity within 5% in a rat, but the iterative TEW was superior to the modified TEW in removing cross-talk in regions of mostly In-111.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Prior, Paul

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Prior, Paul. An Iterative-Triple-Energy Window Approach to Cross-Talk Correction in Quantitative Small Animal Tc-99m and In-111 Single Photon Emission Computer Tomography. Master's thesis, Carleton University, 2014. https://hdl.handle.net/20.500.14718/32377