Measurement of Polymer Concentration and Optimization of Sludge Dewatering Using UV-VIS Spectroscopy
Abstract
dc:description.abstractOptimization of conditioning and dewatering processes is a continuing challenge for wastewater treatment plants. This study investigated the use of UV-Vis spectroscopy to measure and optimize the polymer dose during water and wastewater treatment. Residual polymer concentrations were also measured using two other methods (N-Bromination and Dye Method) and results were compared with the UV-Vis method. UV-Vis method was found to be more sensitive than the other methods in environmental samples. In addition, the study established a relationship between the optimum polymer dose and residual polymer concentration in filtrate using UV-Vis absorbance measurements at 190 nm. Results showed that the UV-Vis method could be a potential in-line tool for real-time optimization of polymer dose during sludge dewatering and other processes that rely on coagulation and flocculation of solids.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science (M.App.Sc.)
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Engineering, Environmental
- Grantor dc:publisher
- Carleton University
- Year dc:date.issued
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Aghamir-Baha, Saman
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
- Language dc:language.iso
- en