Back to search

Carleton University

Fire Performance of Hybrid Timber Connections

Abstract

dc:description.abstract

Wood is being widely used as a construction material; however, the use of wood has been restricted by building codes because it is combustible. Hybrid building systems involve the use of heavy timber in combination with other materials. A hybrid timber connection is considered as the weakest link in this construction system particularly under fire exposure. Analysis of hybrid timber connections is complicated because the behavior and properties of the different materials are different under fire exposure.This study aims at investigating the effect of different parameters on the fire performance of hybrid connections between a glulam beam and a steel column by conducting full scale tests and finite element modeling. The experimental part of this research consisted of a series of full-scale tests conducted in compliance with CAN/ULC-S101. Three different types of connections were investigated, Concealed shear tabs, Exposed shear tabs with 2 and 4 bolts and Seated connections with one bolt and without a bolt. Two sizes of bolts 12.7 mm and 19.1 mm were used and each connection was tested for three load ratios 30%, 60% and 100%.Test results showed that the Seated connection without a bolt outperformed the Exposed and Concealed connections. It was noticed that at 100% load ratio the failure times for all connections were less than 40 minutes. Lowering the load ratio from 100% to 30% increased the failure time by 50 to 72%. Increasing the bolt size reduced the failure time by 20 to 48 %. Reducing the number of bolts from 4 to 2 increased the failure time by 10 to 86% and removing the bolt from the Seated connection increased the failure time by 50 to 125%. The final failure mode was always brittle / splitting of wood, even when ductile failure (yielding of bolts or crushing of wood) was the governing mode in ambient design. Three empirical formulas are proposed by the author to calculate the failure time for design purposes for the three different connections.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Civil
Grantor dc:publisher
Carleton University
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ali, Sabah

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ali, Sabah. Fire Performance of Hybrid Timber Connections. Doctoral thesis, Carleton University, 2016. https://hdl.handle.net/20.500.14718/38907