Back to search

Carleton University

Retrospective Analysis of Permanent Prostate Implants Based on Patient-Specific Monte Carlo Dose Calculations

Abstract

dc:description.abstract

Current dose calculations for permanent prostate implant brachytherapy are performed using the American Association of Physicists in Medicine TG-43 formalism, where dose distributions are derived for a homogeneous water phantom in the absence of inter-seed effects. Using a model-based approach, this study investigates differences in dosimetry, radiobiological endpoints, and clinical outcomes, compared to the clinical TG-43 formalism. Post-implant CT images are used to derive unique virtual patient phantoms (water- and tissue-based) for a cohort of patients. With the use of the Monte Carlo (MC) approach to dose calculations, radiation transport and dose deposition is simulated in these virtual phantoms. Dose and volume metrics are extracted for all the patients and comparisons between the tissue- and water-based approaches are made. Dosimetric quantities are shown to vary between the tissue- and water-based approaches for the prostate and organs-at-risk, with dose overestimation of up to 9.12% in the prostate using the water-based approach.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Haidari, Ali-Reza Mehan

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Haidari, Ali-Reza Mehan. Retrospective Analysis of Permanent Prostate Implants Based on Patient-Specific Monte Carlo Dose Calculations. Master's thesis, Carleton University, 2017. https://hdl.handle.net/20.500.14718/39452