Back to search

Carleton University

Quantitative Imaging With a Pinhole Cardiac SPECT CZT Camera

Abstract

dc:description.abstract

This work develops methods to quantify absolute activity measurements with a multi-head pinhole cardiac SPECT camera that uses cadmium-zinc-telluride (CZT) detectors (Discovery NM530c, GE Healthcare). A central component of absolute activity quantification is the correction for Compton scattered photons. A modified Dual Energy Window (DEW) scatter correction (SC) method was developed that compensates for the presence of unscattered photons in the lower-energy window used to measure scatter. The DEW-SC method was validated using phantom experiments. The mean error in absolute activity measurement was 5 ± 4 % when correcting for attenuation, scatter and the partial volume effects. Clinical accuracy was assessed using 99mTc-tetrofosmin myocardial perfusion images obtained on the NM530c and comparing to DEW scatter-corrected images acquired on a conventional SPECT camera for the same patient. DEW-SC images acquired on the NM530c had increased noise but had summed perfusion scores that were not significantly different from those acquired on the conventional SPECT camera. To reduce noise in scatter corrected images and provide a more accurate estimate of scatter, a model-based SC method was developed based on the analytical photon distribution (APD) approach. Using physical phantom experiments and a set of five clinical studies, the accuracy of APD-SC was evaluated and compared to DEW-SC. Images generated using the model-based method agreed well with acquired data. APD-SC images had lower noise than DEW-SC images and provided a more accurate measure of cardiac activity in high-scatter scenarios. The developed methods provide an accurate means of correcting for scatter and thereby allow the absolute quantification of pinhole cardiac SPECT images.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pourmoghaddas, Amir

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Pourmoghaddas, Amir. Quantitative Imaging With a Pinhole Cardiac SPECT CZT Camera. Doctoral thesis, Carleton University, 2016. https://hdl.handle.net/20.500.14718/39767