Back to search

Carleton University

RADPOS System as a Dose and Position Quality Assurance Tool for 4D Radiotherapy with CyberKnife

Abstract

dc:description.abstract

The CyberKnife system uses Synchrony Motion Tracking to compensate for respiratory motion. This complex radiotherapy system needs independent performance verification to assure safe treatments. In this work, the RADPOS 4D dosimetry system is used to verify CyberKnife's motion tracking and delivered dose. RADPOS motion measurements are compared with Synchrony log files containing internal metal fiducial positions determined using orthogonal kV x-ray imaging, and external LED marker positions determined using a stereoscopic camera system. RADPOS dose measurements are compared with radiochromic film measurements and treatment planning system calculations. The standard deviation of the differences between RADPOS and LED measurements or RADPOS and fiducial measurements were <1 mm along all directions of motion. Percent comparisons between the treatment planning system, RADPOS, and film dose values were mostly within 2 standard deviations of experimental uncertainties. This work demonstrates that RADPOS is a useful tool for the independent quality assurance of CyberKnife treatments.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Marants, Raanan

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Marants, Raanan. RADPOS System as a Dose and Position Quality Assurance Tool for 4D Radiotherapy with CyberKnife. Master's thesis, Carleton University, 2016. https://hdl.handle.net/20.500.14718/39853