Back to search

Carleton University

An MCNP Feasibility Study for a Switchable Radioactive Gamma Source for SPECT Gamma Camera Calibration or Blood Irradiation

Abstract

dc:description.abstract

Gamma radiation sources are used for a multitude of applications, including nuclear medicine applications. The current study investigated the feasibility of a switchable radioactive gamma source for two applications: as a calibration source for SPECT gamma cameras; and as a blood irradiator. The source was based on a sequence of (α, n) reactions followed by (n, γ) reactions. MCNP5 parametric studies were performed to investigate the effects of different moderators (e.g., heavy water, deuterated polyethylene or high density polyethylene), neutron absorbers (e.g., Sm(natural) or Gd(natural)) and geometries, on the calculated gamma flux and dose rate for the proposed source design. The results show that, although technically feasible, the applicability of the proposed source for the two intended applications is not feasible because of cost constraints for larger source designs, and low gamma fluxes and dose rates obtained for smaller source designs.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (M.App.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Engineering, Biomedical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dranga, Ruxandra Ioana

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Dranga, Ruxandra Ioana. An MCNP Feasibility Study for a Switchable Radioactive Gamma Source for SPECT Gamma Camera Calibration or Blood Irradiation. Master's thesis, Carleton University, 2016. https://hdl.handle.net/20.500.14718/39876