dc:description.abstract

The objective of this thesis is to determine the suitability of an air source heat pump water heater (HPWH) for Canadian climates. The performance of a commercially available HPWH was evaluated at a series of air temperature and humidity set-points representing outdoor conditions in Canadian climates. The resulting cost of energy in each climate was compared to the cost when using the unit with basement air and when using an electric water heater. A computer model was developed to simulate the annual performance of the unit when installed in a house and coupled with a heat recovery ventilator (HRV). The effects of the HRV on the performance of the HPWH were found to be negligible when the heating and cooling loads were taken into consideration. It was found that HPWHs have a lower cost of energy than electric water heaters in regions with time-of-use utility rates.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (M.App.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Engineering, Mechanical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Smith, Patrick John Andre

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Smith, Patrick John Andre. Analyzing the Performance of a Heat Pump Water Heater When Coupled with a Heat Recovery Ventilator for Heating Applications in Canada. Master's thesis, Carleton University, 2018. https://hdl.handle.net/20.500.14718/40052