Abstract
dc:description.abstractThe experimental study was carried out to assess the suitability of three proprietary post-installed anchors from Simpson Inc. for use under high strain-rate loading, such as blast loadings, in both tension and in shear. The anchors investigated included two torque-controlled expansion anchors (Strong Bolt® 2, Wedge-All®) and a screw anchor (Titen HD®) . While three different diameters (6.4 mm, 9.5 mm and 12.7 mm) of the Strong Bolt® 2 and Titen HD® anchors were investigated, only two diameters (9.5 mm and 12.7 mm) of Wedge-All® anchors were investigated. The anchor capacities under static loading conditions with average strain rate of 3.0 × 10-4/s were compared with those for impact-loads with average strain rate of 1/s to define a Dynamic Increase Factor (DIF). The failure modes under both conditions were also assessed to ascertain the change as the loading rate increased.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science (M.App.Sc.)
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Engineering, Civil
- Grantor dc:publisher
- Carleton University
- Year dc:date.issued
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Abdul-Hamid, Aliu
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
- Language dc:language.iso