Back to search

Carleton University

Impact of Pinhole Collimation on SPECT Image Quality Metrics, and Methods for Patient-Specific Assessment of Noise and Standardization of Imaging Protocols

Abstract

dc:description.abstract

Dedicated cardiac pinhole SPECT camera designs offer improvements in overall sensitivity, thereby enabling the use of lower injected radiotracer activity and shorter imaging times than parallel-hole designs. The effect of these novel camera designs on image noise on a voxel-by voxel level has not previously been investigated. This work identifies position and orientation-dependent variability of spatial resolution in the field-of-view (FOV) of pinhole cameras. It also identifies a 1.7-fold gradient in the magnitude of image noise across the length of the heart which leads to a 1.3-fold gradient in standard deviation values for a normal database for attenuation corrected images acquired with a commercially available cardiac pinhole camera. This pattern of noise varies with different patients and with different positioning of the heart within the FOV. Thus, to assist with clinical interpretation, a new 1-minute post-processing technique is developed to provide a patient-specific image of the noise distribution which may augment normal database information. Changes in attenuation result in varying levels of noise between patients of different body habitus administered the same radiotracer activity. A method for creating weight-based protocols is developed that standardizes the average noise in cardiac perfusion images by tailoring the radiotracer activity and acquisition time to the body mass of each patient. Methods developed in this thesis allow for more patient-specific imaging protocols, thereby standardizing the image noise level and providing physicians with more information about the noise and spatial-resolution distribution to aide in image interpretation.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cuddy-Walsh, Sarah Grace

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Cuddy-Walsh, Sarah Grace. Impact of Pinhole Collimation on SPECT Image Quality Metrics, and Methods for Patient-Specific Assessment of Noise and Standardization of Imaging Protocols. Doctoral thesis, Carleton University, 2019. https://hdl.handle.net/20.500.14718/40503