Back to search

Carleton University

Experimental Verification of 4D Monte Carlo Simulations of Dose Delivery to Moving and Deforming Anatomies

Abstract

dc:description.abstract

The aim of this work was to validate a 4D Monte Carlo (MC) dose calculation tool (4DdefDOSXYZnrc/EGSnrc) by comparing dose calculations with measurements in rigid and deforming anatomies. This 4DMC approach, that is based on the voxel warping method, calculates the cumulative dose by including continuous motion/deformation of anatomy and motion of linac components. We present how motion recorded during dose delivery combined with deformation/displacement vectors and delivery log files can be used to incorporate motion of the anatomy and treatment units into simulations. Dose deliveries were performed on an Elekta Infinity linac with Agility MLC for static and volumetric modulated arc therapy treatments on the stationary and breathing states of the phantoms. The dose was measured with film (point dose and dose profile) and the RADPOS 4D dosimetry system (point dose).Preliminary validations were done using a phantom with a rigidly moving lung insert. To evaluate the performance of 4DMC simulations in a more realistic condition a programmable deformable tissue-equivalent lung phantom was developed. The lung inserts in both phantoms served the purpose of holding film as well as a spherical tumor to hold RADPOS. RADPOS detectors were also placed outside the tumor in the deformable phantom. Sinusoidal (both phantoms) and irregular (deformable phantom) respiratory traces were tested. Point dose agreements between simulations and measurements were within 2σ of experimental and/or positional/dose reading uncertainties. The agreement between dose profiles from measurements and simulations were determined to be within 2%/2 mm.We also present Monte Carlo modeling of the Elekta linac used in this work. A detailed model was created in BEAMnrc/EGSnrc and model parameters were adjusted through appropriate measurements. We demonstrate how using a simple virtual source model of a linac can help study the sensitivity of the isocentric photon fluence to several beam parameters for small radiation fields. Finally, we present how we can use MC simulations and the virtual source model to explain dose discrepancies observed between film measurements and calculations obtained from the Monaco treatment planning system. The results show that proper model parameters can heavily impact the accuracy of dose calculations of small fields.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gholampourkashi, Sara

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Gholampourkashi, Sara. Experimental Verification of 4D Monte Carlo Simulations of Dose Delivery to Moving and Deforming Anatomies. Doctoral thesis, Carleton University, 2019. https://hdl.handle.net/20.500.14718/40506