Back to search

Carleton University

Improved Arterial Input Function For Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using Phase and T1 Measurements

Abstract

dc:description.abstract

Perfusion is a bodily function that describes the transport of blood and nutrients to an organ. If characteristics of the blood flow to an organ can be measured, clinically useful quantitative data about the organ can be obtained. This is particularly useful in the diagnosis of tumours as their rapid and poorly-formed capillary network is unique compared to healthy tissue. Tumour perfusion information can be obtained by performing Dynamic Contrast-Enhanced (DCE)-MRI. Using DCE-MRI, blood flow into a tumour from a nearby artery can be computed by measuring the concentration of an injected contrast agent as a function of time. This measurement, known as the arterial input function (AIF), can be computed based on the change of either the intensity or the phase of the MR signal from the blood, due to the presence of a contrast agent. While both methods can be used to acquire the AIF, the change in phase is preferred due to its superior accuracy. Even so, the method conventionally used to obtain the phase-derived AIF has deficiencies that lead to an AIF intensity overestimation. The goal of this thesis was to determine a better method to obtain AIF data for patients with brain tumours by using a combination of MR signal phase and accurate T1 relaxation measurements. This was done by first characterizing and deriving equations for phase measurement errors and simulating these effects on the AIF using realistic, clinical parameters. T1 measurement methodology was developed and validated in static-water phantoms and applied to a flowing-water phantom system on which phase AIF data were also acquired. The novel AIF method was tested on this system before it was applied clinically to patients diagnosed with high-grade gliomas. The differences between the quantitative perfusion parameters from the new method and previous AIF methods were compared. The novel AIF measurement method presented in this thesis was designed to be less prone to experimental error than current clinical methods. Theoretical predictions, computed simulations, experimental work with MRI test objects, and clinical results all show that the new method for measuring the AIF is significantly superior to procedures currently used clinically.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Majtenyi, Nicholas

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Majtenyi, Nicholas. Improved Arterial Input Function For Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using Phase and T1 Measurements. Doctoral thesis, Carleton University, 2020. https://hdl.handle.net/20.500.14718/40738