Back to search

Carleton University

Biomedical Signal Quality Analysis for Electromyography

Abstract

dc:description.abstract

Electromyogram (EMG) signals can provide valuable insights into muscle activation and health; however, achieving high-quality signals is challenging. EMG signals are susceptible to contamination, and the acquisition of high-quality EMG signals often requires lengthy setup times and experienced technicians. EMG signal quality analysis is an important domain of research to increase EMG integration into clinical practice, wearable devices, and long-term monitoring. This thesis develops techniques to assess EMG signal quality to improve the ease of EMG acquisition. A literature review of methods for EMG signal quality analysis was conducted. Key areas for further research were identified, including improved selection of high-quality channels within EMG arrays. A process for establishing a ground truth of EMG signal quality based on expert human ratings was developed and used to label an EMG dataset. The intra-rater reliability ranged from 0.76–0.90, and the inter-rater agreement was 0.83, indicating good reliability and that the human rated datasets could be used for future assessments. An automated method of quantifying EMG signal quality was developed in two stages. In Stage I, poor-quality EMG channels were detected and reconstructed. An interpolation-based method of detecting and reconstructing poor-quality channels in high-density EMG (HD-EMG) was developed. Compared with two other detection methods (root mean square and normalized mutual information), the interpolation-based method was most effective for identifying poor channels in HD-EMG (precision 95.0%, recall 100%). Reconstruction of poor-quality channels was best performed with a 2-dimensional spline interpolation (correlation = 0.99). In Stage II, machine learning was explored to distinguish between adequate, good, and excellent channels. A random forest regression model provided the best overall result with Spearman correlations of 0.90, 0.91, 0.74, and 0.73 for inter-electrode distances of 10, 20, 30, and 40 mm, respectively. The recommended EMG feature set was an amplitude-based feature (e.g., root mean square) combined with frequency-based feature(s) (e.g., mean frequency). In single channel EMG, the Spearman correlation dropped to 0.55; however, there was potential to distinguish between adequate and excellent quality channels. The automated methods for quantifying EMG signal quality developed in this thesis will lead to improved efficiencies and lower costs for EMG acquisition.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Electrical and Computer
Grantor dc:publisher
Carleton University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Farago, Emma Jessie

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Farago, Emma Jessie. Biomedical Signal Quality Analysis for Electromyography. Doctoral thesis, Carleton University, 2023. https://hdl.handle.net/20.500.14718/40958