Reconstruction of a Radioactive Source Distribution using a Tomographic Spatial-unfolding Method with Compton Gamma Imager Measurements

Abstract

dc:description.abstract

Advanced detection and reconstruction techniques are utilized to characterize the distribution of radioactive materials in radiological safety and security operations. Most radioactive materials can be detected through their gamma-ray emissions. There may arise circumstances in which the measurement of these gamma rays must be made from behind a pre-established perimeter, however. To address this, Natural Resources Canada (NRCan) and the National Research Council Canada (NRC) have jointly developed novel Compton gamma imaging technology for use in safety and security applications. Compton gamma imaging utilizes the physics of Compton scattering to locate gamma-ray sources, making the technology well-suited to localization at a distance from the suspected source. A fast tomographic reconstruction method has been developed for use with Compton gamma imaging measurements to provide rapid, in situ source localization. For a more precise o ine reconstruction of the data, a spatial unfolding technique has also been developed that ts the observed experimental tomogram with tomographicresponse templates produced by Monte Carlo simulation of spatially-localized sources of radioactivity. These methods have been applied to two sets of experimental data using measurements acquired with the detector developed by NRCan and the NRC. In one experiment, measurements of a Cs-137 point source were acquired in a laboratory setting. In a second experiment, measurements of a spatially-extended La-140 source were acquired in realistic outdoor operational conditions. The tomographic reconstruction of the sources takes only minutes and demonstrates good localization capability. The spatial-unfolding method shows good localization of experimentally-measured sources but underestimates their activity, while accurately recovering the activity of synthetic sources. The underestimation of experimentally-measured source activities is ascribed to limitations in the simulated representation of the detector response and environmental terrain not included in the simulated world. The simple tomographic reconstruction method will be useful in guiding radiological safety and security operations in near real-time. The post-process unfolding method will further be useful in informing follow-on consequence management operations and remediation activities.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Murtha, Nathan

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Murtha, Nathan. Reconstruction of a Radioactive Source Distribution using a Tomographic Spatial-unfolding Method with Compton Gamma Imager Measurements. Doctoral thesis, Carleton University, 2021. https://hdl.handle.net/20.500.14718/41088