Back to search

Carleton University

An Inverse Model-based Approach to Estimate Air Infiltration in Commercial Buildings using Occupant-generated CO2 and Humidity

Abstract

dc:description.abstract

Monitoring air infiltration continuously is of great importance to detect building envelope degradation over time. However, environmental factors often make the accurate measurement of air infiltration challenging. Further, fan pressurization and tracer gas tests possess certain drawbacks limiting their applicability in commercial buildings. Thus, this research proposes a low-cost inverse model-based approach for estimating infiltration rates by using existing carbon dioxide (CO2) and humidity data. The laboratory tracer gas tests were carried out to explore the effectiveness of replacing sulphur hexafluoride (SF6) with CO2. A field study was conducted using both CO2 and water vapour. The historical CO2 and humidity data were also used to train the model. At last, air handling unit (AHU) return air CO2 concentration data were utilized to demonstrate this novel approach. The results indicated that the proposed method could conveniently lend itself to estimate air infiltration rates at a reasonable accuracy using existing sensor data.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (M.App.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Engineering, Civil
Grantor dc:publisher
Carleton University
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Xiong, Zijun

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation