Carleton University
A Novel Metrology Standard for Synchrotron Produced Monochromatic X-ray Beams
Abstract
dc:description.abstractPurpose: X-ray beams produced using synchrotrons have unique properties that are of interest to radiotherapy investigations and the characterization of radiation detectors. To facilitate the use of synchrotron-produced photons in such investigations, this project aims to determine the absorbed dose to water at depth for synchrotron-produced monochromatic x-ray beams with a standard uncertainty less than 1 %, significantly lower than current methods. Methods: The absorbed dose to water at a depth of 2 cm, D(w,2 cm), was evaluated using a purpose built novel aluminum calorimeter design. Finite element modeling and radiation transport simulations were performed to refine the design, calculate correction factors, and assess influence quantities. Two iterations of the design were constructed to test calorimeter operation and a comparison of the quantity air kerma, using a secondary microDiamond detector, was performed. Results: The combined standard uncertainty in the determination of absorbed dose to water was estimated to be 0.89 %, and was found to be constant for monochromatic energies investigated (80 keV to 140 keV). No dependence on calorimeter design was observed and the comparison with the microDiamond detector showed agreement in the determination of air kerma rate at the 1.5 % level, providing confidence in the new calorimeter standard. Conclusions: This new calorimeter has been shown to accurately determine absorbed dose to water in synchrotron-produced x-ray beams with a substantially lower uncertainty compared to current methods. Routine operation has also been demonstrated, providing a new high-accuracy dosimetric tool for users of synchrotron beams, initially in Canada but potentially at sites worldwide.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (Ph.D.)
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Physics
- Grantor dc:publisher
- Carleton University
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- El Gamal, Islam Mohamed Medhat
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
- Language dc:language.iso
- en