dc:description.abstractThe use of wood as structural elements in buildings is very common in Canada. However, because wood is combustible, the National Building Code of Canada restricts the use of wood to smaller buildings compared to noncombustible buildings. Wood to steel connections, composed of heavy timber, steel plates and bolts, are used to assemble wood components together. The fire performance of timber connections is complex due to the variety of connection types, geometries and fastener arrangements, as well as the properties of the materials under fire exposure. This study investigates the fire performance of timber-to-steel bolted connections under tension loading by conducting fire tests, developing finite element models, and creating simplified empirical calculation methods. Two types of timber-to-steel bolted connections considered in this study are wood-steel-wood (WSW) and steel-wood-steel (SWS). In the experimental testing of this research, a series of full-scale fire tests was conducted on these connections loaded in tension exposed to either the standard CAN/ULC-S101 or anon-standard time-temperature fire curves. Results showed that the fire resistance of all WSW and SWS connections were less than 45 min, which is a minimum fire-resistance rating for Canadian code compliance. The results also showed that the WSW specimens lasted longer during the tests compared to the SWS specimens of the same size. The comparison between the CAN/ULC-S101 tests versus the non-standard fire scenarios showed that the non-standard time-temperature curve is more severe. In the modelling part of this research, a three-dimensional finite element thermo-mechanical model of WSW and SWS connections was produced. Comparison between the model results and experimental testing indicated that both the thermal and structural models predicted the specimen temperatures and failure of the connections fairly well. Finally, an empirical calculation method was created to estimate the fire-resistance rating of WSW and SWS connections. This calculation method is based on fire-resistance methodology in CSA O86’s Annex B for large-cross-section wood elements and strength reduction factors at elevated temperatures from CSA S16’s Annex K for steel elements. The predictions of fire resistance using the empirical calculation method can accurately estimate the fire resistance of both WSW and SWS connections.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (Ph.D.)
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Engineering, Civil
- Grantor dc:publisher
- Carleton University
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Alam, Marc
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
- Language dc:language.iso
- en