Back to search

Carleton University

Development and characterization of aptamer-conjugated imaging tools for diagnostic applications

Abstract

dc:description.abstract

Magnetic resonance imaging (MRI) and computed tomography (CT) are imaging modalities commonly used to assess blood flow; however, neither can label a blood clot that may either disrupt flow, causing an ischemic stroke, or have the ability to demonstrate where a cerebral hemorrhage has occurred (hemorrhagic stroke). To improve the diagnosis and treatment of blood vessel diseases, such as stroke and aneurysms, we developed fibrinogen aptamer (FA)-functionalized contrast agents, enabling the identification and labelling of blood clots. Fibrin was chosen as the target of interest as it a major constituent of aforementioned conditions. Since FA was originally selected to bind fibrinogen, fibrin-binding validation was required. It was hypothesized that FA would retain some binding affinity towards the polymerized form, fibrin, given that most of the structural elements of fibrinogen remain unmodified in the final form. To assess the affinity and selectivity of FA towards non-solution-based fibrin, FA was tagged with a green emitting fluorophore and fluorescence co-localization was monitored. Solubilized fibrin was also used in a number of binding validation studies, including microscale thermophoresis, isothermal titration calorimetry, and circular dichroism. These techniques were used to calculate the apparent Kd, which was found to be within the acceptable range. Four different FA-targeted contrast materials were produced, including gadolinium conjugates (Gd(III)-DOTA/NOTA-FA) for MRI, iodinated-FA and FA-functionalized gold nanoparticles (FA-AuNPs) for CT, and FA-functionalized gold-coated iron-oxide nanoparticles (FA-Fe3O4-AuNPs) as dual-imaging agents for MRI and CT. All formulations were tested for their ability to produce significant contrast enhancement. In each case, when treated with aptamer-targeted formulations, contrast development was specific to the location of the clot. In MRI, T1- and T2-weighted scans revealed hyperintense contrast enhancement of fibrinogen in the blood pool and fibrin clots, respectively. In CT, both iodo-FA and FA-AuNPs showed high positive contrast enhancement, confirming that targeting minimizes dilution of the contrast material in the presence of the blood pool. FA-Fe3O4-AuNPs were successful in producing clot-specific hypointense contrast in MRI, allowing for delineation of clot parameters. However, CT imaging demonstrated that higher concentrations of the nanoparticles is required, and the thin gold coating is not sufficient to produce contrast enhancement.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Chemistry
Grantor dc:publisher
Carleton University
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Koudrina, Anna

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Koudrina, Anna. Development and characterization of aptamer-conjugated imaging tools for diagnostic applications. Doctoral thesis, Carleton University, 2020. https://hdl.handle.net/20.500.14718/41495