Back to search

Carleton University

Hygrothermal Analysis of Vacuum Insulation Panels in New and Retrofit Walls for Canada

Abstract

dc:description.abstract

In Canada, residential buildings account for 16.7% of the total secondary energy end use and 12.7% of the total greenhouse gas emissions. Of these percentages, space heating and cooling account for about two-thirds of the total. As buildings are being built to higher standards, an air-tight, resilient, and thermally efficient building enclosure could be used to meet the targeted energy efficiency in new and retrofit construction. The research program was aimed at the use of vacuum insulation panels (VIPs) encapsulated within expanded polystyrene (EPS) board to form an exterior insulation system for use in new and retrofit construction nationwide. The program utilized experimental and numerical methods to evaluate the insulation system under steady-state thermal and transient hygrothermal conditions. The experimental study was split into two categories: steady-state thermal conductivity testing and in-situ hygrothermal monitoring. The steady-state testing, performed with a guarded hot-box at Carleton University, found that a 200 mm by 300 mm (8" x 12") VIP in the exterior insulation with a 1:1 VIP to EPS insulated area ratio on a code-built wood-frame wall would have an effective thermal resistance of R-5.1 to R-6.3 m2K/W. It was observed after the in-situ monitoring, performed at CanmetENERGY-Ottawa, that the backer material for the VIP-insulated system did not affect the long-term potential for mould growth or moisture-related damage in the assembly. The numerical study was performed using WUFI Pro 6.1 and WUFI 2D. The hygrothermal model was validated using the in-situ monitored data from 2016 to 2020 for Ottawa, CA. A methodology to model VIP insulated wall assemblies for building envelope retrofits was presented and performed in multiple cities across Canada. It was observed that masonry clad buildings (e.g., brick veneer) and wet climates (e.g., Vancouver and St. John's) had a higher potential to experience mould growth in new and retrofit buildings, for a similar envelope construction in a dryer climate. Finally, a screening study of eleven simulation inputs was performed using WUFI Pro 6.1 by following the Morris Method, a One-At-a-Time (OAT) screening procedure that compares the standard deviation and mean of the peak mould index.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Mechanical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Conley, Brock Paul

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Conley, Brock Paul. Hygrothermal Analysis of Vacuum Insulation Panels in New and Retrofit Walls for Canada. Doctoral thesis, Carleton University, 2022. https://hdl.handle.net/20.500.14718/41935