Back to search

Carleton University

Patient-Specific Planning Target Volume Margins for Liver Stereotactic Robotic Radiosurgery

Abstract

dc:description.abstract

Purpose: To implement patient-specific planning target volume (PTV) margins for liver radiation therapy treatments. Methods and Materials: Treatment log files are analyzed to assess tumour motion-tracking accuracy. A uniform PTV margin is estimated that considers motion-tracking errors and deformations, provided that the impact of uncorrected rotations is minimized. A supervised machine learning algorithm is used to investigate if motion-tracking errors are less than 2 mm, and consequently, the standard PTV margins can be reduced by 2 mm. We employ a warning system that quantifies the probability of a geographic miss if the PTV margin is reduced for every subsequent fraction. A dosimetric analytical tool is proposed to retrospectively assess the dose to a target against different types of delivery errors. The tool is validated by radiochromic film measurements for liver and trigeminal neuralgia treatments. Case studies are conducted to access the suitability of a selected PTV margin based on the geometrical and dosimetric coverage of targets. The range of rotations that can be safely allowed for trigeminal neuralgia treatments is quantified since rotational corrections cannot be applied by the system for this specific disease site. Results: Isotropic 4 mm PTV margins are sufficient to account for tracking errors and deformations for 95% of patients. The accuracy of predicting if motion-tracking errors are less than 2 mm is 0.84 ± 0.06 using 5-fold cross-validation. Using the warning system, 11 out of 64 cases predicted to be treated with 2 mm reduced PTV margins might require replanning, but for each fraction they have more than 96% of target(s) encompassed by the reduced PTV. For experiments with different types of geometrical errors the dose measurements agree well (2%/2 mm level) with the dose distributions estimated using the dosimetric analytical tool. Dose to targets considering delivery errors can be significantly improved if treatments are planned following certain guidelines. For trigeminal neuralgia treatments, target rotations of up to 1° can be safe for some patients. Conclusions: It is feasible to implement patient-specific PTV margins in the clinic, assisted with an early-warning system and dosimetric analytical tool to warn of a potential geographic miss and underdosing of target(s).

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Liu, Ming

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Liu, Ming. Patient-Specific Planning Target Volume Margins for Liver Stereotactic Robotic Radiosurgery. Doctoral thesis, Carleton University, 2021. https://hdl.handle.net/20.500.14718/41964