Back to search

Carleton University

Data-Driven Patient Motion Compensation in Cardiac Positron Emission Tomography

Abstract

dc:description.abstract

Positron emission tomography (PET) is a molecular imaging modality that has been demonstrated to be a powerful, non-invasive, tool for the assessment and diagnosis of cardiac pathologies like coronary artery disease. The accuracy of these clinical examinations for detecting and prognosticating disease can be marred in cases where patient motion is severe. Clinical use of motion tracking/compensation tools, however, is relatively uncommon partly due to the increases in complexity and time of patient setup prior to imaging. The purpose of the work described here was to develop and evaluate new methods of patient motion detection and compensation in the context of cardiac PET imaging studies that are less complex than standard commercial options in the hope of reducing barriers to clinical adoption. The proposed methods are based on measuring and tracking the motion of a low-activity radioactive marker placed on patients using the positron emission tracking (PeTrack) algorithm. Motion information was employed to compensate and/or correct for either respiratory or whole-body patient motion. The performance of PeTrack for respiratory tracking and motion compensation was evaluated in a clinical population in comparison with a commonly used commercial optical tracking device. Within a practical comparison framework PeTrack was shown to perform comparably to the commercial system. From this comparison shortcomings of both PeTrack and the commercial system were identified; knowledge of the former can inform future development and improvement. A method for whole-body patient motion correction (WBMC) in static cardiac perfusion studies using PeTrack was developed. Motion corrected images demonstrated significantly less blurring of the myocardial walls and improved contrast. Relative perfusion measurements among the clinical data sets were not significantly affected although the extent of patient motion was limited. The WBMC algorithm was extended for dynamic acquisitions used for quantification of myocardial blood flow. Motion detection and estimation with PeTrack was compared to that of another data-driven motion tracking algorithm within a clinical population. Body motion estimation with PeTrack was more robust than the alternative method. Motion correction using PeTrack demonstrated improvement among various quality indicators of the kinetic modelling used to estimate blood flow.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Manwell, Spencer Thomas

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Manwell, Spencer Thomas. Data-Driven Patient Motion Compensation in Cardiac Positron Emission Tomography. Doctoral thesis, Carleton University, 2020. https://hdl.handle.net/20.500.14718/41986