Back to search

Carleton University

Design and Construction of a Double-Layer PVDF Wearable Ultrasonic Sensor for the Quantitative Assessment of Muscle Contractile Properties

Abstract

dc:description.abstract

Assessment of the skeletal muscle contractile properties provides valuable information for various medical applications. This thesis presents the development of a wearable ultrasonic sensor (WUS) and a method to measure the skeletal muscle contractile parameters. The proposed WUS was made of flexible polyvinylidene fluoride (PVDF) piezoelectric polymer film. A double-layer PVDF configuration was proposed to improve ultrasonic performance such as ultrasound signal strength. In order to study the double-layer PVDF WUS performance for its design consideration, a formulation of a numerical simulation model for the double-layer PVDF WUS was derived, based on Mason's equivalent circuit model of piezoelectric resonators. The double-layer PVDF configuration and the effects of non-piezoelectric layers on ultrasonic performance, such as backing, bonding, and electrode layers, were studied in detail using the simulation model developed to obtain a guideline for the design and construction of double-layer PVDF WUS. The construction procedure of the proposed design of the double-layer PVDF WUS was simple and relatively low-cost. The experimental evaluation showed the improved ultrasound performance of the developed double-layer PVDF WUS. The flexibility, lightweight, thinness, and small size of the double-layer PVDF WUS enable a steady attachment to the skin surface without affecting the underlying tissue motion in the area of interest. Such features could reduce the motion artifacts in the ultrasound measurement of tissue thickness. The developed double-layer PVDF WUS was tested for in vivo measurements of the skeletal muscle contractile parameters. Comparative measurements of the electrically-evoked static contractions of a skeletal muscle were performed by the developed double-layer PVDF WUS and the laser displacement sensor (LDS). The double-layer PVDF WUS demonstrated less variability in the extracted contractile parameters than the LDS. In addition, it was verified that the double-layer PVDF WUS was less susceptible to the motion artifacts induced by the body/limb motion than the LDS. The contractile parameters were successfully extracted from the tissue thickness changes measured by the double-layer PVDF WUS during voluntary and tetanic contractions. Furthermore, the muscle tetanic progression level was quantitatively assessed using the fusion index (FI) parameter obtained.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Electrical and Computer
Grantor dc:publisher
Carleton University
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Almohimeed, Ibrahim

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Almohimeed, Ibrahim. Design and Construction of a Double-Layer PVDF Wearable Ultrasonic Sensor for the Quantitative Assessment of Muscle Contractile Properties. Doctoral thesis, Carleton University, 2021. https://hdl.handle.net/20.500.14718/42029