Back to search

Carleton University

Building Integrated Sub-Slab Thermal Storage System for Coupling to a Heat Pump: Modelling, Optimization, and Thermal Performance

Abstract

dc:description.abstract

Canada, like most countries around the world, has adopted targets for reducing the green gas emissions associated with the built environment. In addition to reducing green gas emissions, goals for improving the resilience to climate change, and making buildings energy-wise, more comfortable, and more affordable, were adopted as well. In this context, low energy, and net zero energy buildings are becoming a target in the research field, through the incorporation of renewable energy systems and thermal energy storage among others. The green gas emissions associated with the energy use in buildings can be significantly reduced by taking an integrated approach for heating, cooling, ventilation, dehumidification, and domestic hot water heating when designing new buildings, or retrofitting existing ones. The research investigates the performance of a sub-slab ground heat exchanger, coupled to a heat pump system, and the ability of the system to provide space conditioning and domestic hot water heating for a low-rise multi-unit residential building. The thermal performance of the system was assessed through simulation for a multi-unit residential construction in Ottawa. Simulations using weather files for other five locations in different climate zones across Canada were conducted as well, to assess the suitability of the system to other climate conditions. Parametric analyses were conducted to optimize both the design of the building and of the ground heat exchanger. Appropriate control strategies were investigated also to optimize the energy consumption of the heat pump and the auxiliary equipment. According to the results, the system is able to fully meet the space conditioning and domestic hot water heating needs of the building. The annual electricity consumption of the heat pump was estimated to be 11.4 GJ per dwelling unit. Adding the energy use associated with lights and appliances, and all the auxiliary equipment, the total energy consumption of a dwelling unit was 24.4 GJ. Considering the average annual energy consumption of a dwelling unit in low-rise multi-unit residential building as 46.7 GJ, the investigated system can achieve approximately 40% reduction of the energy use.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Mechanical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dumitrascu, Luminita

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation