Back to search

Carleton University

Optimization of primary beam for x-ray dual-mode imager comprising radiography and coherent scatter

Abstract

dc:description.abstract

Medical, industrial, and security x-ray systems should give images that demonstrate material contrast for accurate identification. Novel devices use both coherently-scattered x rays and primary to acquire images. In our system, the same detector is used for primary and scatter. The primary information being detected post object must be attenuated so that both the primary and scatter are within the detector’s dynamic range. Initially, we used 1.5-mm-thick post-object attenuator disks of 90% tungsten/10% copper alloy. In this work, we investigate whether reducing the incident beam’s x-ray tube potential and using less attenuating materials can increase primary image quality. Our final attenuating material is 1.0 mm cerium. This scales all three of primary signal-to-noise-ratio, signal size, and signal-difference-to-noise-ratio by approximately a factor of 10. The scatter values remained relatively unchanged. Additional filtration placed upstream at the collimator could bear further investigation.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kemdirim, David

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kemdirim, David. Optimization of primary beam for x-ray dual-mode imager comprising radiography and coherent scatter. Master's thesis, Carleton University, 2024. https://hdl.handle.net/20.500.14718/43046