Next-Generation Sequences of Operation for Occupant-Adaptive Building HVAC Systems
Abstract
dc:description.abstractOccupant-centric control (OCC), which adapts building systems based on occupants’ presence or preferences, represents a promising alternative to the way buildings are traditionally controlled. However, poor sequences of operation can degrade the benefits of OCC. An analysis of two buildings before and after the initial COVID-19 lockdown --- one with two control logic faults corrected and an occupancy-based ventilation OCC, and one with traditional ventilation --- explored how energy use differed between the two buildings (Chapter 2). A calibrated energy model of the traditionally ventilated building was developed to evaluate how occupancy-based ventilation alongside changes to the sequences of operation impacted energy use. The results showed that OCC savings could be significantly diminished if poor sequences of operation were utilized, and highlighted a need for next-generation sequences of operation that can enable occupant-adaptive HVAC system. In order to enable many OCCs, granular occupant counts are needed. To this end, a methodology for disaggregating building-level occupancy data into zone-level occupant counts using sensor fusion was developed (Chapter 3). With these occupancy data, a practical workflow for implementing and evaluating OCCs via building simulation was created (Chapter 4). EnergyPlus simulations of a nine-office testbed were performed with combinations of OCCs, climates, and envelope assemblies to demonstrate the workflow; the results showed that zone-level demand-controlled ventilation (DCV) and temperature preferences/setbacks during unoccupied hours had the highest savings potential. Given the high cost of sensors, a simulation-based investigation of a case study building was undertaken to determine how DCV, based on the emerging ASHRAE RP-1747 CO2-based DCV approach, could be implemented with minimal sensing infrastructure (Chapter 5). EnergyPlus simulation of the case study building were performed with a variety of occupancy scenarios, sensor positions, and sensor grid densities. Recommendations for sensing infrastructure, as well as proposed changes to ASHRAE RP-1747 were developed. Finally, the next-generation sequences of operation (including zone-level DCV and temperature setbacks) were implemented in a case study building to determine how these changes to operation impact energy use and occupant comfort (Chapter 6). These results will be used to support its adoption by future iterations of ASHRAE Guideline 36.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (Ph.D.)
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Engineering, Building
- Grantor dc:publisher
- Carleton University
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hobson, Brodie William
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
- Language dc:language.iso
- en