Abstract
dc:description.abstractPhotovoltaic/Thermal (PV/T) driven combined cooling, heating, and power (CCHP) systems are a promising low-carbon alternative for meeting building energy demands in the residential sector. This thesis focuses on the development of a novel PV/T driven CCHP topology and corresponding control strategy for use in residential buildings. To achieve the objectives, a research plan comprising three parts is devised. In the first part of the research, a computational fluid dynamic (CFD) - based numerical modelling approach is developed to simulate the operation of a PV/T driven domestic hot water (DHW) system under dynamic conditions. Using the case study location of Ottawa, Canada, 48 different scenarios are developed which involve two different working fluids (i.e., air and a water-ethylene glycol solution) and two PV/T collector design alternatives (i.e., with and without fins) for each month of the year. Results show that the solar fraction is greater in the air-based system than in the water-based system for all months, and values as high as 90.1% and 84.3% are obtained, respectively. In the second part, a numerical model of a PV/T driven CCHP system, controlled via a novel dual-tank latent heat thermal energy storage (LHTES) strategy, is developed in TRNSYS and C++. The system performance is investigated via a case study that considers a three-bedroom home located in Ottawa, Canada. The phase change material (PCM) melting temperature, load loop supply temperature, and LHTES tank height are varied in the analysis resulting in 27 annual simulation scenarios. For the considered simulations, the annual solar and electricity fractions are shown to vary between 10.3% and 39.7%, and 23.2% and 33.2%, respectively. In the third part of the thesis, the performance of the above-mentioned PV/T driven CCHP system is further assessed for use in a low-energy multi-unit residential building. Two North American case study locations representing a heating dominated (Ottawa, CA) and a cooling dominated (Albuquerque, USA) climate are examined by considering two solar collector array area sizes. Results show that operating the system in Albuquerque relative to Ottawa results in an increase in solar fraction and electricity fraction of up to 62% and 40%, respectively.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (Ph.D.)
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Engineering, Mechanical
- Grantor dc:publisher
- Carleton University
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kalkan, Cem
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
- Language dc:language.iso
- en