Carleton University
Root Cause Analysis of Frequency Oscillations Observed in Ontario’s Distribution System
Abstract
dc:description.abstractRecurring frequency oscillations in Ontario’s distribution system have led to multiple false trips of a synchronous generator-based biomass power plant, disrupting operations and raising concerns about system stability. Over an 18-month period, these oscillations, ranging from 5.6 to 6.45 Hz, occurred across various load conditions without any coinciding faults or sudden disturbances. The complexity of the system, coupled with significant uncertainties in system parameters, made traditional modeling approaches impractical. To address this challenge, this thesis introduces a two-phase root cause analysis methodology that integrates data-driven techniques with system modeling. The first phase treats the system as a "black box," utilizing signal processing and feature extraction to identify subtle characteristics of the oscillations without requiring detailed system data. This step enables the narrowing down of potential scenarios responsible for the oscillations. The second phase involves system modeling and sensitivity analysis, leveraging small-signal analysis, the shooting method combined with the Newton-Raphson algorithm, and bifurcation analysis to pinpoint the dominant factors driving instability. The study identifies Hopf bifurcation as a key contributor to the observed oscillations, with systems operating in unity power factor (UPF) mode being particularly susceptible due to reduced load margins compared to those in voltage control (PV) mode. To mitigate the oscillations, control parameters were adjusted based on load margin sensitivity analysis, improving stability across different operating conditions. The proposed solution was validated through Real-Time Digital Simulation (RTDS) and Hardware-in-the-Loop (HIL) testing, demonstrating its effectiveness in eliminating the oscillations and preventing false tripping events. This research contributes a new approach to root cause analysis in power systems with high uncertainty and large-scale complexity. By combining data-driven techniques with targeted modeling, it provides a practical framework for identifying, analyzing, and mitigating oscillations without relying on extensive system data. The findings not only resolve a critical issue in Ontario’s distribution system but also offer insights applicable to broader power system stability challenges.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (Ph.D.)
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Engineering, Electrical and Computer
- Grantor dc:publisher
- Carleton University
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Alizadeh, Mojtaba
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
- Language dc:language.iso
- en