The buildings sector is a major contributor to global CO2 emissions, with a significant share stemming from heating, ventilation, and air-conditioning (HVAC) systems. Occupancy patterns and preferences have undergone significant changes, particularly after the COVID-19 pandemic. The dependence of building stakeholders on conservative schedules and setpoints can result in significant energy waste. Additionally, using fixed schedules and setpoints disregards variations in occupants' behaviour and preferences, compromising their comfort. In response to these challenges, a growing field of research has emerged focusing on occupant-centric controls (OCC), an approach that adapts building operations based on real-time occupant presence, behaviour, and system feedback. This study introduces reinforcement learning-based (RL) algorithms for zone-level and system-level HAVC controls. At the zone level, an RL algorithm is created to learn occupant thermal preferences from their thermostat interactions with the goal of saving energy while maintaining comfort. At the system level, a comparative study is conducted for the common supply air temperature (SAT) setpoint reset strategies under cases of unusual occupancy patterns and occupant thermal preferences in a simulation environment. In light of this comparative study, an RL-based SAT setpoint reset strategy is developed to address the gaps in these conventional methods. In the measurement and verification phase, the thermal preference learning algorithm is adapted to be fit for field implementation. It is, then, deployed in an academic facility to test its performance with real occupants. The research objectives are to develop RL algorithms for both zone-level and system-level HVAC controls that quantify energy savings and evaluate occupant comfort impacts. The proposed OCC algorithms are designed to adapt to varying occupant preferences and different building and environmental conditions. The implementation results of the thermal preference learning algorithm have shown energy savings up to 12%. Additionally, the simulation results of the proposed SAT setpoint reset method based on RL have shown better energy use and occupants' comfort than the common strategies. The simulations and implementations also demonstrate the compatibility and robustness of the proposed algorithms. This study investigates the shift of the design and operation of HVAC systems from the "one-size-fits-all" approach to an "occupant-centric" approach.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Building
Grantor dc:publisher
Carleton University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Elehwany, Hussein Mostafa Hussein

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Elehwany, Hussein Mostafa Hussein. Developing and Testing Reinforcement Learning-based Occupant-Centric Control Algorithms for HVAC Systems. Doctoral thesis, Carleton University, 2025. https://hdl.handle.net/20.500.14718/44847