Back to search

Carleton University

Development of a robust thermal calibration methodology for pyroelectric calorimeters

Abstract

dc:description.abstract

Ultra-high dose rate (UHDR) beams can induce the FLASH effect, reducing healthy tissue toxicity while maintaining tumour control. However, accurate reference dosimetry remains a barrier to clinical adoption. This work investigates pyroelectric materials, which generate current from temperature changes, as the basis for a calorimeter compatible with clinical electrometers. Prototypes using films, ceramics, and crystals were developed, with custom holders ensuring reliable electrical contact. Thermal calibrations in a remotely controlled bath enabled measurement of pyroelectric coefficients, which were comparable to literature values despite some variability. Initial calibration plots showed multi-valued responses caused by air gaps; redesigned holders reduced multi-valuedness and improved accuracy. Reproducibility testing identified detector disassembly as the primary variation source. Preliminary irradiations showed agreement between the pyroelectric and a reference graphite calorimeter. These findings underscore the impact of detector design on dosimeter performance and support the potential of pyroelectric calorimeters for reliable use in UHDR beam applications.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Howard, Victoria Elizabeth Valerie

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Howard, Victoria Elizabeth Valerie. Development of a robust thermal calibration methodology for pyroelectric calorimeters. Master's thesis, Carleton University, 2025. https://hdl.handle.net/20.500.14718/44877