Back to search

Carleton University

Vibration and Sound Exposure During Neonatal Patient Transport

Abstract

dc:description.abstract

Neonates make up the smallest sized patients that may require medical transport between hospitals. In Ontario, Canada, a standard Neonatal Patient Transport System (NPTS) is used to ensure interoperability between teams, ambulance services, and facilities. This system is designed to provide monitoring and support to patients, and satisfy standards for medical equipment in emergency medical service environments. However, these systems demonstrate complex dynamic properties. Elevated motions of the NPTS, including the transport incubator and patient within, have been observed by transport staff during typical use. High levels of whole-body vibration (WBV) and sound are known to have harmful effects on the human body. This has motivated the need to characterize and reduce elevated vibration and sound levels. To improve the system, the current transport environment must be understood. A series of field tests have been performed to measure vibration and sound within various transport environments. The focus was mainly on air ambulances, but ground ambulances and intra-hospital transport were also investigated. Spectral analysis of the data provided insight into the unique vibration profiles of each ambulance type. A series of laboratory experiments were performed to simulate the vehicle motions and examine the response of the transport system. Conditions which induced amplified or attenuated motions were identified. The system's response to vibration mitigation strategies, such as alternative mattress types or the use of vibration isolators, was evaluated. These experiments have shown to successfully replicate the air ambulance motions and enable further testing of different mitigation strategies. This thesis presents a framework for evaluating the response of a neonatal transport system to real transport conditions. Comprehensive testing of a neonatal transport system to this degree has not been performed before. These novel experimental methods can be applied in future studies with different transport systems, different vehicle profiles, and to evaluate new attenuation strategies. This work has also motivated external interest in further neonatal transport system research, resulting in new collaborations with other transport teams and industry leaders. The contributions of this thesis support the ongoing efforts to develop a solution to this complex and critical problem.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Aerospace
Grantor dc:publisher
Carleton University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gibb, Keely Claire

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Gibb, Keely Claire. Vibration and Sound Exposure During Neonatal Patient Transport. Doctoral thesis, Carleton University, 2026. https://hdl.handle.net/20.500.14718/45085