Hygrothermal Performance Testing of Magnesium Oxide Structural Insulated Sheathing Panels in Canada

Abstract

dc:description.abstract

Magnesium oxide construction materials are fire and mould resistant and can reduce the embodied carbon of buildings. Contrastingly, they have a history of moisture-related durability concerns. This thesis aimed to design an experimental setup to evaluate a magnesium oxide structural insulated sheathing panel under controlled hygrothermal conditions. Fifteen wall assemblies were subjected to controlled climate conditions. One wall assembly was designed to impose a controlled moisture addition simulating a cladding defect. The deconstruction process found discolouration and evidence of high moisture levels within sheathing panels. A calibrated 1D hygrothermal model for one wall showed good agreement with measurements. The validation models justified the simplified modelling techniques of a cladding defect and of extreme wetting events. This thesis showed that under the tested conditions this magnesium oxide building product did not exhibit the severe moisture-related failures seen historically with similar products.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (M.App.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Engineering, Mechanical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Scharf, Nick Christian George

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Scharf, Nick Christian George. Hygrothermal Performance Testing of Magnesium Oxide Structural Insulated Sheathing Panels in Canada. Master's thesis, Carleton University, 2026. https://hdl.handle.net/20.500.14718/45243