Back to search

Chalmers University of Technology

Transient Simulation of Ventilation Rate and Moisture load for Cold Attic Constructions - A CFD Analysis

Abstract

dc:description.abstract

In this Master's thesis, numerical modeling of transient air, heat and mass transport is investigated in a principal cold attic construction through the use of the commercial CFD software ANSYS Fluent. A numerical model that was developed and validated for steady state simulations in an earlier project is now being used for transient simulations over a total time of 24 hours to capture the daily variations in temperature and humidity levels. The attic model contain wooden joists lying in a layer of insulation at the bottom of the attic, and a triangular shaped air cavity. Natural convection due to the temperature gradients between the hot floor and the cold roof along with forced convection driven by the ventilation system is investigated. An hygrothermal analysis and numerical methods are applied to estimate the moisture load at the inner roof boundary for different ventilation rates. The project has been performed as a collaboration between ÅF Industry AB and the Division of Building Technology at Chalmers University of Technology.

Degree

thesis:*
Level thesis:degree_level
H
Department dc:contributor.department
Chalmers tekniska högskola / Institutionen för bygg- och miljöteknik
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hellsvik, Ragnar

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Chalmers University of Technology
Base URL
odr.chalmers.se/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hellsvik, Ragnar. Transient Simulation of Ventilation Rate and Moisture load for Cold Attic Constructions - A CFD Analysis. H thesis, 2015. https://hdl.handle.net/20.500.12380/228064