Back to search

Chalmers University of Technology

A comparison between low-cost and professional RTK equipment under forest conditions

Abstract

dc:description.abstract

Real time kinematic (RTK) is an important differential GNSS positioning method. It is widely used in forestry investigation. Depending on the type of reference station, RTK technique can be divided into traditional RTK and the advanced network RTK. There are also different types of GNSS receivers, for example the low-cost mapping type and the professional surveying type. The surveying type devices tend to have more accurate results, but the price difference between the two types of receivers can be dozens of times, and surveying type receivers are usually too bulky to carry and move around in the forest. Therefore, it is worthwhile to analyze if there are any situations that low-cost traditional RTK devices can achieve a comparable per formance as the professional network RTK devices do. In this project, we compared the performance of a low-cost mapping type receiver, u-blox F9P, with a professional network RTK device, Leica GS18 I. Field measure ments were taken in two days in the forests near Gothenburg. Measurements were taken in different percentages of canopy closure, different canopy directions and different tree species. Standard deviations and positional errors of the collected po sitions were calculated. Variables like dilution of precision (DOP), age of differential (AoD), sky plot and time to fix were also collected. It is found that the real time correction messages (RTCM) communication range for u-blox was at least 500 m in flat area, but terrain obstacles might reduce the range limit by half. The u-blox device performed bad when the canopy closure was over 50% or 65%, with a positional error of over 50 cm, thus it is not recommended to replace Leica network RTK with u-blox in dense forests. In most cases the standard deviation of Leica was better than that of u-blox. DOP was an important factor that had strong correlations with errors, fix status and cycle slips. Data collection with u-blox should wait for 1∼5 minutes after power-on, until DOP becomes lower and stable. AoD is found not much related with the error, but there should not be obvious break with the communication of RTCM. Canopy directions influenced the error but had less impact than canopy closure. The relationship between the error and tree species was not able to be determined.

Degree

thesis:*
Level thesis:degree_level
H
Department dc:contributor.department
Chalmers tekniska högskola / Institutionen för rymd-, geo- och miljövetenskap
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wan, Yiqing
Advisors dc:contributor.supervisor
  • Isoz, Oscar
  • Hedekvist, Per-Olof
Committee member dc:contributor.committeemember
  • Johansson, Jan

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Coursecode
seex30

Chain of custody

source
Harvested from
Chalmers University of Technology
Base URL
odr.chalmers.se/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Wan, Yiqing. A comparison between low-cost and professional RTK equipment under forest conditions. H thesis, 2024. https://hdl.handle.net/20.500.12380/307644