Abstract
dc:description.abstractThe aim of this thesis was to develop and validate an offline method for monitoring human walking and running using a single, low-cost Inertial Measurement Unit (IMU). We designed signal-processing algorithms to count steps, estimate distance and speed, and classify activity level. All from the 3-axis accelerometer and gyroscope data. Raw signals were filtered with low-pass Finite Impulse Response (FIR) filter, zero-velocity updates were applied at each detected gait event and dominant stride frequencies were extracted via Fast Fourier Transform (FFT) over sliding windows. In test with five subject on a 75 m straight path, step-count accuracy averaged 98% for walking and 94% for running. The distance estimates reached 96% accuracy in walking and 91% in running. Activity classification achieved 100% accuracy in controlled trials and 89% in mixed scenarios.
Degree
thesis:*- Level thesis:degree_level
- M2
- Department dc:contributor.department
- Chalmers tekniska högskola / Institutionen för elektroteknik
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Wäneskog, Vendela
- Wiklund, Alexander
- Strandlycke, Philip
- Sillén, Lukas
- Törnkvist, David
- Carlsson, Gustav
- Advisor dc:contributor.supervisor
-
- Amani, Elina
- Committee member dc:contributor.committeemember
-
- Brännström, Fredrik
Subjects
dc:subject × 7Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Dc Identifier Coursecode
- EENX16