Back to search

Clemson University

A comparison of the ZnS(Ag) scintillation detector to the silicon semiconductor detector for quantification of alpha radioactivity in aqueous solutions

Abstract

dc:description.abstract

A ZnS(Ag) detector was successfully used in the direct detection of alpha particles from aqueous solutions and the results were compared to the passivated ion implanted planar silicon (PIPS) continuous air monitor (CAM) detector. The ZnS(Ag) detector is recommended for on-line detection of gross alpha radioactivity from high-level liquid waste process streams; however, the detector suffers from limitations due to variations in detection efficiency with alpha energies. The beta and gamma interference did not significantly spillover into the alpha region of interest of the ZnS(Ag) detector which provided absolute detection efficiencies of 7.19 ± 0.13%, 5.37 ± 0.02%, and 4.21 ± 0.03% for Cm-244, Pu-239, and U-234/U-238 solutions, respectively. The detection efficiencies were found with a 3.5 mg/cm_ ZnS(Ag) scintillation layer, 4.15 cm_ detection surface, and a 5.2 mm air gap between the liquid surface and the detector. The absolute detection efficiencies of the PIPS CAM detector for Cm-244, Am-241, Pu-239, and Th-230 solutions in the presence of beta and gamma activity were 4.61 ± 0.01%, 3.87 ± 0.01%, 2.84 ± 0.01%, and 1.32 ± 0.01%, respectively, for a geometrical set-up similar to the Zn(Ag) experiments. Two ZnS(Ag) scintillator thicknesses were compared. The thicker scintillation layer suffered from light absorption and scattering in the ZnS(Ag) layer resulting in a lower energy signal. Despite the differences, the absolute detection efficiencies of the two thicknesses were equivalent. The large detection area available to the ZnS(Ag) detector proved to be valuable for the detection of radioactivity in liquids as the absolute detection efficiency more than doubled for a surface area of 78.5 cm_ and resulted in a minimum detection concentration of 0.32 Bq/mL for U-238 solution for a 3600 second count. The detection capabilities and pulse height spectra of the ZnS(Ag) detector were compared to the PIPS CAM detector as well as computer simulations and theory.

Degree

thesis:*
Name thesis:degree_name
Master of Arts (MA)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Environmental Engineering and Science

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Foster, Jennifer
Contributors dc:contributor
  • DeVol, Timothy A

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Repository record dc:identifier
https://open.clemson.edu/all_theses/10

Chain of custody

source
Harvested from
Clemson University
Base URL
open.clemson.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Foster, Jennifer. A comparison of the ZnS(Ag) scintillation detector to the silicon semiconductor detector for quantification of alpha radioactivity in aqueous solutions. Thesis thesis, https://open.clemson.edu/all_theses/10